07/2020
Corona II
– LED Line Scan Illumination
PMA_CHR_CD40069_R05_Manual_Corona-II_XLC4
79
6.3.6 PWM interface / external switch X6
LED controller XLC4-1 and XLC4-1A
Pin
Name
Notes
1
ON
IN
switch signal for PWM mode operation
2
PWC
IN
control signal for PWM mode operation
3
ENC
IN
(don’t use)
4
FAIL
OUT
failure signal
5
STAT
OUT
(don’t use)
6
COMMON
common signals for pins 1-5
7
SW1
switch
8
SW2
switch
Connector Type:
Würth Elektronik:
691 325 110 008
Counterpart:
Würth Elektronik:
691 364 100 008
The Signal ON switches the illumination in PWM-Mode.
The Duty Cycle of Signal PWC controls LED current in PWM-Mode.
The FAIL Signal signals Error States in PWM Mode, Bulb Mode and Analog Mode.
For a detailed description of the logical behavior of this signals, see section 6.5.3.3.
The two Inputs ON and PWC are opto-coupled inputs with a common GND line COMMON.
The Output Signal FAIL is also opto-coupled with an open collector circuit to COMMON.
LED controller XLC4-1F4
Pin
Name
Notes
1
ON_1
IN
External LED control channel A
2
ON_2
IN
External LED control channel B
3
ON_3
IN
External LED control channel C
4
FAIL
OUT
failure signal
5
STAT
OUT
(don’t use)
6
COMMON
common signals for pins 1-7
7
ON_4
External LED control channel D
8