07/2020
Corona II
– LED Line Scan Illumination
PMA_CHR_CD40069_R05_Manual_Corona-II_XLC4
104
6.5.2.15 Command IP (set and read IP address / set addressing mode)
The command IP is used to read and modify the IP address of the XLC4 and to change the
addressing method.
Command
Notes
CommandID
IP
IP works in all XLC4 operating modes
Parameter
None
mode
ip_address
Parameter
Value
Description
None
Controller send a response message with
the current values for
mode
and
ip_adress
mode
“M”
Static IP address (default)
“D”
DHCP addressing
ip_adress
valid IP address string
e.g.: 192.168.87.234 (default)
Response
ip , space , mode , space , ip_address
General notes
Changes are applied after next power-up.
Examples:
IP
#Read addressing mode and address
ip M 192.168.87.234
#XLC4 is in static IP mode
IP M
#Change addressing mode
ip M 192.168.87.234
IP 192.168.87.234
#Change IP address
ip M 192.168.87.234