07/2020
Corona II
– LED Line Scan Illumination
PMA_CHR_CD40069_R05_Manual_Corona-II_XLC4
109
6.5.2.21 Error codes
If a command is erroneous, an error response is generated instead of the standard response.
Examples:
MU 1
er 100
# unknown command
IY K 500
er 101
# unknown parameter
IY A 4000
er 102
# parameter out of range
If an internal error is detected, an error message is appended to the standard response.
Example:
TE
te 70-80,71,23-21,22;er 202,A
Table of error codes:
Number Description
100
Unknown command
101
Unknown parameter
102
Parameter out of range
103
200
Supply voltage exceeds limits
201
Analog control voltage exceeds limits
202
LED Voltage out of range
203
Output voltage exceeds limits
(programmed in the Corona)
204
Warning temperature exceeded
205
Maximum temperature exceeded
206
Shutdown active
210
Write error to EEPROM in Driver Unit
211
Read error from EEPROM in Driver Unit
212
Write error to EEPROM in Corona
213
Read error from EEPROM in Corona
214
Fan failure detected at ACTRL
215
Programmable voltage value out of range
(programmed int the controller)