Page 26 of 40 IRIS Connect Series Engineering Manual Version 1.8
Inputs
Setup the Inputs (Pins) function between SMS messaging (IRIS Connect Duo only), SIA Alarm format or Contact ID
alarm format.
Note: One alarm format for the Pins (SIA or CID) can be selected and then setup individual pins to be SMS messaging
if required.
When changing the pin format between one of the alarm formats (SIA or CID) a warning message will be received to
indicate that all pins will be setup for this alarm format and returned to the default allocation shown below, as pins
cannot be setup to different alarm formats.
SMS (IRIS Connect Duo only)
On input ‘Set’ (open circuit) and input ‘Restore’ (close circuit) the IRIS Connect will send the configured SMS message
for the ‘Set’ or ‘Restore’ text, to the configured phone number.
Selecting SMS for the input format will display the following options to
configure for each pin as shown.
Phone no
Phone number used to send the SMS messages.
Set text / Restore text
Setup the ‘Set’ and ‘Restore’ messages to be sent to the entered phone
number. The maximum length for the text message is 24 characters.
Inverse
The function of the inputs ‘Set’ and ‘Restore’ can also be inverted to be
the opposite way round by ticking the ‘Inverse’ tick box. This will mean
that the ‘Set’ is now the closed circuit and the ‘Restore’ is open circuit.
Enable
Enable/disable each pin input with the ‘Enable’ tick box.
Monitor Cable
There is also the option to monitor the input for tamper which is
detailed in
Section 7.7 “Pin Inputs”
.