3 Introduction to Use
3.1 Preparation before Use
25
attenuator
power range of the receiver.
008 pulse measurement
1
Used for measuring the RF S-parameter of pulse.
S10 time domain measuring device
1
Used for measuring the time domain, and
determining and analyzing the discontinuous
locations of appliances, clamps or cables.
S80 frequency offset measuring device
1
Used for measuring the frequency offset, in
millimeter wave THz, expandable.
S82 mixer scalar measuring device
1
Used for measuring the mixer scalar parameter.
S83 mixer vector measuring device
1
Used for measuring the mixer vector parameter.
S84 embedded local oscillator converter
measuring device
1
Used for measuring the embedded local
oscillator converter.
S86 gain compression and two-dimensional
sweep measuring device
1
Used for gain compression and two-dimensional
sweep measurement.
S87
active
intermodulation
distortion
measuring device
1
Used for measuring the active intermodulation
distortion signal.
AV3672A/B accessory:
AV31121 calibrating device
FB0HA0HB025.0
B0HA0HC025.0
1
1
1
Used for overall calibration.
3.5mm amplitude-stabilized phase-compensated
cable, used for overall measurement.
3.5mm amplitude-stabilized phase-compensated
cable, used for overall measurement.
AV3672C accessory:
AV31123 calibrator
FE0BN0BM025.0
FE0BN0BL025.0
1
1
1
Used for overall calibration.
2.4mm amplitude-stabilized phase-compensated
cable, used for overall measurement.
2.4mm amplitude-stabilized phase-compensated
cable, used for overall measurement.
AV3672D accessory:
AV31123A calibrator
FE0BN0BM025.0
FE0BN0BL025.0
1
1
1
Used for overall calibration.
2.4mm amplitude-stabilized phase-compensated
cable, used for overall measurement.
2.4mm amplitude-stabilized phase-compensated
cable, used for overall measurement.
3.1.1.2 Environmental Requirements
The operation place of AV3672 series vector network analyzers should conform to the following environmental
requirements.
1) Operating environment
The operating environment should conform to the following requirements.
Table 3.2 Operating Environment Requirements of AV3672
Temperature
0°C-40°C
Temperature range of error
adjustment
23°C±5°C (allowable temperature deviation in error adjustment: <1°C)
Humidity
If the temperature is lower than +29°C, the measurement range of the humidity
meter should be 20% to 80%, without condensation.
Altitude
0-2,000m (0-6,561 feet)
Vibration
Max. 0.21G, 5-500Hz
Summary of Contents for AV3672 Series
Page 3: ......
Page 4: ...AV3672 Series Vector Network Analyzer Contents...
Page 5: ......
Page 124: ...5 Menu 5 1 Menu structure 120 5 1 2 Track Fig 5 2 Track Menu...
Page 125: ...5 Menu 5 1 Menu structure 121 5 1 3 Channel Fig 5 3 Channel Menu...
Page 126: ...5 Menu 5 1 Menu structure 122 5 1 4 Excitation Fig 5 4 Excitation Menu I...
Page 127: ...5 Menu 5 1 Menu structure 123 Fig 5 5 Excitation Menu II...
Page 128: ...5 Menu 5 1 Menu structure 124 Fig 5 6 Excitation Menu III...
Page 129: ...5 Menu 5 1 Menu structure 125 5 1 5 Response Fig 5 7 Response Menu I...
Page 130: ...5 Menu 5 1 Menu structure 126 Fig 5 8 Repsonse Menu II...
Page 131: ...5 Menu 5 1 Menu structure 127 Fig 5 9 Response Menu III...
Page 132: ...5 Menu 5 1 Menu structure 128 Fig 5 10 Response Menu V Fig 5 11 Response IV...
Page 133: ...5 Menu 5 1 Menu structure 129 5 1 6 Calibration Fig 5 12 Calibration Menu...
Page 134: ...5 Menu 5 1 Menu structure 130 5 1 7 Marker Fig 5 13 Cursor Menu I...
Page 135: ...5 Menu 5 1 Menu structure 131 Fig 5 13 Cursor Menu II...
Page 136: ...5 Menu 5 1 Menu structure 132 Fig 5 15Marker Menu III...
Page 137: ...5 Menu 5 1 Menu structure 133 5 1 8 Analysis Fig 5 16 Analysis Menu I...
Page 138: ...5 Menu 5 1 Menu structure 134 Fig 5 17 Analysis Menu II...
Page 139: ...5 Menu 5 1 Menu structure 135 Fig 5 18 Analysis Menu III...
Page 140: ...5 Menu 5 1 Menu structure 136 5 1 9 System Fig 5 19 System Menu I...
Page 141: ...5 Menu 5 1 Menu structure 137 Fig 5 20 System Menu I...
Page 254: ...8 Basis of Network Measurement 8 3 Amplifier Parameter Specifications 250...
Page 257: ...8 Basis of Network Measurement 8 4 Complex Impedance 253...
Page 373: ...Appendix Appendix 4 Pulse Measurement 369 Fig 4 9 Receiver gain configuration Dialog Box...