![China Electronics Technology Instruments AV3672 Series User Manual Download Page 158](http://html1.mh-extra.com/html/china-electronics-technology-instruments/av3672-series/av3672-series_user-manual_2601790158.webp)
5 Menu
5.2. Description of menu
154
Function description:
Select this menu to display the impedance curve.
Parameter description:
None
13) Format
Function description:
If this menu is selected, the display format table will pop up. Multiple format curves can be selected.
Parameter description:
None
5.2.5.3 Scale
This menu is used to set the scale. Click it to enter the menu of lower level. The specific menu includes:
Table 5.14 Format
Menu
Autoscale
Autoscale All
Scale
Electrical Delay
Phase Deviation
Amplitude Deviation
Scale Coupling
1) Autoscale
Function description:
If this menu is selected, the vertical scale will be selected automatically so that the active trace can be better
displayed in the vertical grid of the screen. The stimulus is not affected, and only the scale value and reference
value are changed.
The appropriate scale factor will be selected so that data can be displayed in 80% of the screen.
Select the center value of the trace on the screen according to the reference value.
Parameter description:
None
2) Autoscale All
Function description:
If this menu is selected, the appropriate scale will be set for all traces in the window so that the trace can be better
displayed in the vertical grids of the window.
Parameter description:
None
3) Scale
Function description:
Select this menu and enter the set scale value.
Summary of Contents for AV3672 Series
Page 3: ......
Page 4: ...AV3672 Series Vector Network Analyzer Contents...
Page 5: ......
Page 124: ...5 Menu 5 1 Menu structure 120 5 1 2 Track Fig 5 2 Track Menu...
Page 125: ...5 Menu 5 1 Menu structure 121 5 1 3 Channel Fig 5 3 Channel Menu...
Page 126: ...5 Menu 5 1 Menu structure 122 5 1 4 Excitation Fig 5 4 Excitation Menu I...
Page 127: ...5 Menu 5 1 Menu structure 123 Fig 5 5 Excitation Menu II...
Page 128: ...5 Menu 5 1 Menu structure 124 Fig 5 6 Excitation Menu III...
Page 129: ...5 Menu 5 1 Menu structure 125 5 1 5 Response Fig 5 7 Response Menu I...
Page 130: ...5 Menu 5 1 Menu structure 126 Fig 5 8 Repsonse Menu II...
Page 131: ...5 Menu 5 1 Menu structure 127 Fig 5 9 Response Menu III...
Page 132: ...5 Menu 5 1 Menu structure 128 Fig 5 10 Response Menu V Fig 5 11 Response IV...
Page 133: ...5 Menu 5 1 Menu structure 129 5 1 6 Calibration Fig 5 12 Calibration Menu...
Page 134: ...5 Menu 5 1 Menu structure 130 5 1 7 Marker Fig 5 13 Cursor Menu I...
Page 135: ...5 Menu 5 1 Menu structure 131 Fig 5 13 Cursor Menu II...
Page 136: ...5 Menu 5 1 Menu structure 132 Fig 5 15Marker Menu III...
Page 137: ...5 Menu 5 1 Menu structure 133 5 1 8 Analysis Fig 5 16 Analysis Menu I...
Page 138: ...5 Menu 5 1 Menu structure 134 Fig 5 17 Analysis Menu II...
Page 139: ...5 Menu 5 1 Menu structure 135 Fig 5 18 Analysis Menu III...
Page 140: ...5 Menu 5 1 Menu structure 136 5 1 9 System Fig 5 19 System Menu I...
Page 141: ...5 Menu 5 1 Menu structure 137 Fig 5 20 System Menu I...
Page 254: ...8 Basis of Network Measurement 8 3 Amplifier Parameter Specifications 250...
Page 257: ...8 Basis of Network Measurement 8 4 Complex Impedance 253...
Page 373: ...Appendix Appendix 4 Pulse Measurement 369 Fig 4 9 Receiver gain configuration Dialog Box...