Notic e for Maintain Ge nerator
:
1.Do not mistake the polarit y of IG connection pole and L connection pole.
2.The line between IG connection pole and L connection pole should not be short circuit, do remember to pass through
the charging indicator lamp when connect them.
3. There should be no load between the IG coil and E pole.
2
.
Equipment position figure of
charging circuit
starting and
Tim e for batterry to take in the
charging current under each voltage:
Voltage
A more than 16........4h
B 14-15.9................. .......8h
C less than 13.9........ ........16h
:
:
:
:
A CC Rel ay
Starter relay
Starter motor 30A fuse Sb2
Ignition switch relay
Ignition s witch 5A fu se Fb24
Front relay box
P ositive fu se box
Battery
The
ing
charg ing circui t is shown as figure 8-1. The charging
system is a system charging the battery with the output electricity o f the AC
generator .
When the ignition switch is connected, curren t flows into the
excitation coil, and the coil is initially powere d. When the engine starts ,
stator coil begin to generate electricity , the exci tation coil is powered by the
output current of stator coil.
The output power of th e AC gen erator inc reases with the augment of
excitation current. And dec reases wi th the fall of the current. When the
battery voltage
(
the voltage of the S end of AC gene rator) reaches the
adjusting voltage, the exci ation current is cut off. And when the
start
and
t
battery
voltage is less than the adjusting volta ge , the v oltage adjustor controls the
excitation current to adjust the output voltage and keep it invariableness.
Gnerator B
1#pin of starter
positive connectio n fuse box FB28-
battery positive pole
vehic le body ground
、
engine ground
ground line.
When the ignition switch is at the ST position, battery voltage-positive
line fuse box 80A fuse Fb29
5A fuse Fb24
6# pin of ignition switch
4#
pin of ignition switch
85# pin of starter relay
86# pin of starter relay
31ground line
battery voltage
positive line fuse box 80A fuse Fb29
30A fuse
Sb2
30# pin of starter relay
87# pin of starter relay
2# pin of starter-
Start suction coil
battery voltage
positive line fuse box 120A fuse Fb28
1# pin of
starter
electromagnetic switch
starter
ground.
(
1
)
The first grade control circuit
(
2
)
The second grade control circuit
(
3
)
Main circuit
1
.
Chargin g circuit
2
.
Starting circuit
→
→
→
→
→
→
→
→
→
→
→
→
→
→
→
→
→
→
→
→
→
→
→
starter-ground.
2# pin of starter
keep coil
ground.
3
.
Starting and Charging System Circuit analyse
Generator
12
Summary of Contents for A21 2005
Page 10: ...1 A21 ENGINE PDF created with pdfFactory Pro trial version www pdffactory com ...
Page 17: ...8 PDF created with pdfFactory Pro trial version www pdffactory com ...
Page 248: ......
Page 298: ......
Page 301: ... 5 5 8 7 5 0 LDJUDP H SODQDWLRQ LVWULEXWLRQ RI 9DULRXV DUWK 3RLQWV DQG 0DLQ 0RGXOHV ...
Page 303: ... 6 RQQHFWRU 6 5 5 8 7 5 0 211 725 127 8 RQQHFWRU 8 ...
Page 313: ... 12 5 5 8 7 5 0 GMXVWLQJ 6 XVH ER 6HDW DGMXVWLQJ V VWHP ...
Page 323: ... 5 5 8 7 5 0 12 FLJDUHWWH XVH ER V VWHP 1 7 21 ...