P2M066STD-Ver1.0
18
GB
Main Parameters
Parameter
Folder (Usr)
Meaning
Value
U00
Buzzer sounding duration. (
0 = buzzer disabled
).
10s
U08
Chamber probe (
Pb1
) regulation hysteresis.
3
U09
Set the minimum time between compressor switch-off and subsequent
restart.
1
U11
Defrost duration.
13
U13
Needle probe setpoint for positive deep cooling.
3
U14
Needle probe setpoint for negative deep cooling.
-18
U15
Needle probe setpoint for deep negative deep cooling.
-25
U16
Chamber probe setpoint for positive deep cooling.
-5
U17
Chamber probe setpoint for negative deep cooling.
-39
U19
Chamber probe setpoint for continuous (
infinite
) deep cooling.
-40
U20
Chamber probe setpoint for positive storage.
1
U21
Chamber probe setpoint for negative storage.
-22
U22
Chamber probe setpoint for deep negative storage.
-25
U24
Time-based positive deep cooling duration
120
U25
Time-based negative deep cooling duration
280
U27
Maximum negative deep cooling duration as per standards. (
0 = disabled
).
300
U28
Maximum deep negative deep cooling duration. (
0 = disabled
).
0
U29
Maximum infinite negative deep cooling duration. (
0 = disabled
).
0
Parameter
Folder CP
Meaning
Value
rHd
Delay in “setpoint not reached” alarm signaling through displaying the
label “
rHd
”.
15
Parameter
Folde CnF
Meaning
Value
cPd
PAS password value.
111
Summary of Contents for CHABB23T