Operation
-25°C Cycle
Operate as follows to start the Temperature deep freezing cycle:
The temperature-controlled “-25°C cycle” is split in the following 2 phases:
Blast Freezing
Storage
-25°C
cycle is used when the end user wants a safe food operation.
1. To select “-25°C cycle” press and release
key to select the cycle until the display will
show the label “
-25
”: the set led icon, compressor led icon
and “Celsius degree”
led icon
will be
ON.
2. Press and release START/STOP
key to start “-25°C cycle”: the Compressor and Fans
LED icons + will switch
ON
permanently; and the icon
start flashing. On the
display will appear the message “
dEEP
” every 1 minute and the value of needle probe
“
Pb2”
at that moment.
3. Once the needle probe temperature reaches the pre-setting point cycle is ending, a visual
and acustic alarm will notify the ending cycle, the unit will start a storage cycle and led
icon
will flashing.
Note
: During the storage mode the display will show chamber temperature
“Pb1”
.
Frost Bust Cycle (Inf)
Frost bust
cycle is used when the end user wants a long blast freezing cycle with manual ending
(suitable for ice cream).
Operate as follows to start the Frost Bust cycle:
1. To select “Frost Bust cycle” press and release
key to select the cycle until the display
will show the label “
Inf
”: the set
led icon and compressor led icon will be
ON.
2. Press and release START/STOP
key to start Frost Bust cycle: the Compressor and
Fans LED icons +
will switch
ON
permanently; and the icon
start flashing. On
the display will appear “the counter of the minute” and the message “
Inf
” and room
temperature status will be show every 1 minute.
3. This cycle never ending in automatic, to stop the cycle the enduser must push
START/STOP Key.
Summary of Contents for CHABB23T
Page 2: ...1 P2M066STD Ver1 0 GB ...
Page 26: ...25 P2M066STD Ver1 0 DE ...
Page 50: ...49 P2M066STD Ver1 0 FR ...
Page 74: ...73 P2M066STD Ver1 0 ES ...
Page 98: ...97 P2M066STD Ver1 0 PT ...
Page 122: ...121 P2M066STD Ver1 0 IT ...
Page 146: ...145 P2M066STD Ver1 0 IT ...
Page 147: ...P2M066STD Ver1 0 146 IT ...