![Carrier Aquasnap 30RAP010 Product Data Download Page 9](http://html1.mh-extra.com/html/carrier/aquasnap-30rap010/aquasnap-30rap010_product-data_2561845009.webp)
9
Factory-installed options
Novation
®
heat exchanger technology microchan-
nel coil (aluminum fin/aluminum tube) e-coat con-
denser
is available for optimum durability. Novation heat
exchangers with microchannel coil technology are offered
coated or uncoated to match coil protection to site condi-
tions. The Carrier Electronic Catalog (E-Cat) can be used to
determine whether or not corrosion protection is recom-
mended for particular applications in coastal/marine envi-
ronments. Following the input of the requested data, the E-
Cat program output will advise the appropriate coil to be
used. Other factors described in "Selection Guide: Environ-
mental Corrosion Protection, Novation Heat Exchanger
with Microchannel Coil Technology" catalog number 04-
581042-01 must also be considered to determine if corro-
sion protection is required.
Value sound fans
provide a metal, propeller-type fan sys-
tem which is cost-effective when compared to the low-
sound AeroAcoustic™ fan system. This factory-installed fan
option is compatible with the Motormaster
®
V option.
Ultra-low sound
provides a combination of low sound
AeroAcoustic™ fans with sound blankets.
Digital compressor control
allows incremental unload-
ing for a closer match to building load. This option is not
available on the 018 size unit.
High short circuit current rating
provides a short cir-
cuit current rating protection for the unit up to 65,000 A
on 460-v, 380-v, and 208/230-v units or 25,000 A on
575-v units.
Motormaster
®
V low-ambient control
provides con-
trol of fan motor operation to maintain head pressure at
low outdoor ambient temperatures down to –20 F (–29 C)
This option also requires field-installed wind baffles. This
option is also available as an accessory. This option is a
standard feature on all 30RAP010 and 015 chillers.
Non-fused disconnect
includes factory-installed non-
fused disconnect capability for power and control located
at the unit. This is not available on dual point power.
Energy management module (EMM)
provides energy
management capabilities to minimize chiller energy con-
sumption. Several features are provided with this module
including leaving fluid temperature reset, cooling set point
reset or demand limit control from a 4 to 20 mA signal, 2-
point demand limit control (from 0 to 100%) activated by a
remote contact closure, and discrete input for “Ice Done”
indication for ice storage system interface. The EMM is
also available as an accessory.
Freeze protection
with cooler heaters provides protec-
tion from cooler freeze-up to –20 F (–29 C).
GFI convenience outlet
is a factory-installed conve-
nience outlet that includes 4-amp GFI (ground fault
ITEM
FACTORY-INSTALLED OPTION
FIELD-INSTALLED ACCESSORY
Condenser Coil and Sound Options
MCHX E-Coat
X
Low Sound Compressor Blankets
X
Value Sound Fans
X
Ultra-Low Sound
X
Controls/Communication Options
BACnet Communications
X
BACnet Translator Control
X
Chillervisor System Manager III Multi-Unit Control
X
Energy Management Module (EMM)
X
X
LON (Local Operating Network) Translator Control
X
Navigator™ Display
X
Remote Enhanced Display
X
Touch Pilot™ Display
X
Cooler Options
Freeze Protection — Cooler Heaters
X
Remote Cooler Kit
X
Electrical Options
Unit-Mounted Main Disconnect, Non-Fused
(not available with dual point power)
X
GFI Convenience Outlet (115 v)
X
X
High SCCR (Short Circuit Current Rating)
X
Hydronics Option
Hydronic Pump Package
X
Fluid Storage Tank (available on sizes 010-060)
X
Variable Frequency Drive (VFD) (available on sizes 070-090)
X
Refrigeration Circuit Options
Compression Suction Service Valves (available on sizes 070-090)
X
Low Ambient Temperature Head Pressure Control
X
X
Hot Gas Bypass (not available on sizes 010 and 015)
X
X
Digital Compressor (not available on size 01
8
)
X
Security/Packaging Options
Security Grilles/Hail Guards
X
X
Vibration Isolation
X
Wind Baffles
X
Options and accessories
Summary of Contents for Aquasnap 30RAP010
Page 14: ...14 a30 5349 Base unit dimensions 30RAP070 090...
Page 15: ...15 ACCESSORY STORAGE TANK FOR UNIT SIZES 010 015 a30 4879 Accessory dimensions...
Page 16: ...16 ACCESSORY STORAGE TANK FOR UNIT SIZES 018 030 a30 4880 Accessory dimensions cont...
Page 17: ...17 ACCESSORY STORAGE TANK FOR UNIT SIZES 035 060 a30 4881...
Page 60: ...60 600 760 a30 5264 Typical control wiring schematic...
Page 75: ......