![Carrier Aquasnap 30RAP010 Product Data Download Page 3](http://html1.mh-extra.com/html/carrier/aquasnap-30rap010/aquasnap-30rap010_product-data_2561845003.webp)
3
temperature reset, demand limiting,
compressor wear minimization and
protection, temperature and pressure
displays and diagnostic functions.
These controls result in higher chiller
reliability, simplified training and more
productive service calls with corre-
spondingly lower operational and
maintenance costs.
Carrier’s exclusive accessory hand-
held Navigator™ display provides con-
venience and powerful information in
the palm of your hand. The Navigator
display helps technicians to quickly
diagnose problems and even prevent
them from occurring.
All AquaSnap units are ready to
be used with the Carrier Comfort
Network
®
(CCN) system.
A BACnet† communication option
is also available for the i-Vu
®
Open
control system or a BACnet building
automation system.
AquaSnap units minimize the
impact on your footprint, as
well as your bottom line
The integrated hydronics and the
chilled fluid storage tank’s placement
under the chiller minimize the foot-
print, allowing easy installation almost
anywhere.
Novation
®
heat exchanger
technology
The Novation heat exchanger design
with microchannel (MCHX) condenser
coil
is a robust, cost effective alterna-
tive to traditional coil design. These
coils are offered coated or uncoated to
match coil protection to site condi-
tions. The Carrier Electronic Catalog
(E-Cat) can be used to determine
whether or not corrosion protection is
recommended for particular applica-
tions in coastal/marine environments.
Following the input of the requested
data, the E-Cat program output will ad-
vise the appropriate coil to be used.
Other factors described in "Selection
Guide: Environmental Corrosion Pro-
tection, Novation Heat Exchanger with
Microchannel Coil Technology" catalog
number 04-581042-01 must also be
considered to determine if corrosion
protection is required.
Microchannel coils are more robust
than other coil types, making them
easier to clean without causing damage
to the coil.
Due to the compact all aluminum
design, microchannel coils will reduce
average unit operating weight by 25%
compared to the previous 30RA units.
The streamlined MCHX coil design
also reduces refrigerant charge by an
average of 60% compared to the pre-
vious 30RA units.
Run Status
Service Test
Temperature
Pressures
Setpoints
Inputs
Outputs
Configuration
Time Clock
Operating Modes
Alarms
Alarm Status
ENTER
MODE
ESCAPE
PROPELLER FAN
AEROACOUSTIC FAN
1/3 OCTAVE BAND CENTER FREQUENCY (Hz)
SOUND POWER [dB(A)]
AEROACOUSTIC™ FAN vs. PROPELLER FAN
PENETRATES BUILDING
STRUCTURE
25
40
63
130
168
250
400
630
1080
1600
2400
4000
6300
8000
90
85
80
75
70
65
60
55
50
Run Status
Service
Test
Temper
atures
Pressures
Setpoints
Inputs
Outputs
Configur
ation
Time Cloc
k
Oper
ating Modes
Alar
ms
ENTER
ESC
MODE
Alar
m Status
Comf
ort
Link
SCROLLING MARQUEE DISPLAY
NAVIGATOR™ DISPLAY
MODULE
LOW-SOUND AEROACOUSTIC
FAN WITH NIGHTTIME LOW
AEROACOUSTIC FAN VS PROPELLER FAN
TUBE
S
FIN
S
MICROCHANNEL
S
MANIFOLD
NOVATION
®
HEAT EXCHANGER
TECHNOLOGY WITH MICROCHANNEL
CONDENSER COILS
* Under ASHRAE Standard 34-1992, R-410A is
classified as an A1 refrigerant.
† Sponsored by ASHRAE (American Society of
Heating, Refrigerating, and Air Conditioning
Engineers).
Summary of Contents for Aquasnap 30RAP010
Page 14: ...14 a30 5349 Base unit dimensions 30RAP070 090...
Page 15: ...15 ACCESSORY STORAGE TANK FOR UNIT SIZES 010 015 a30 4879 Accessory dimensions...
Page 16: ...16 ACCESSORY STORAGE TANK FOR UNIT SIZES 018 030 a30 4880 Accessory dimensions cont...
Page 17: ...17 ACCESSORY STORAGE TANK FOR UNIT SIZES 035 060 a30 4881...
Page 60: ...60 600 760 a30 5264 Typical control wiring schematic...
Page 75: ......