AIR FLOW
FIELD
POWER
S
UPPLY
CONTROL
WIRING
FLOW
GATE
VALVE
VIBRATION
ELIMINATOR
VALVE
PRE
SS
URE
GAGE
S
HUT OFF
VALVE
S
HEAT TAPE IN
S
ULATION I
S
RECOMMENDED ON ALL EXPO
S
ED PIPING
IF AMBIENT TEMPERATURE <
3
2 F (0 C) AND NO ANTIFREEZE
S
OLUTION I
S
IN
S
Y
S
TEM
TO
EXPAN
S
ION
TANK
PUMP
AIR FLOW
FIELD
POWER
S
UPPLY
CONTROL
WIRING
FLOW
GATE
VALVE
VIBRATION
ELIMINATOR
NOTE 5
HEAT TAPE IN
S
ULATION I
S
RECOMMENDED ON ALL EXPO
S
ED PIPING
IF AMBIENT TEMPERATURE <
3
2 F (0 C) AND NO ANTIFREEZE
S
OLUTION I
S
IN
S
Y
S
TEM
30RAP UNITS WITHOUT HYDRONIC PACKAGE (SIZE 030 SHOWN)
30RAP UNITS WITH HYDRONIC PACKAGE (SIZE 030 SHOWN)
NOTES:
1. Chiller must be installed level to within
1
/
8
in. per foot (10.4 mm per meter) to maintain proper compressor oil return and hydraulics.
2. Wiring and piping shown are general points-of-connection guides only and are not intended for a specific installation. Wiring and piping shown are
for a quick overview of system and are not in accordance with recognized standards.
3. All wiring must comply with applicable local and national codes.
4. All piping must follow standard piping techniques. Refer to Carrier System Design Manual or appropriate ASHRAE (American Society of Heating,
Refrigerating, and Air Conditioning Engineers) handbook for details.
LEGEND
Airflow Through Condenser
Power Wiring
Chilled Water Piping
LEGEND
Airflow Through Condenser
Power Wiring
Chilled Water Piping
NOTES:
1. Chiller must be installed level to within
1
/
8
in. per foot (10.4 mm per meter) to maintain proper compressor oil return and hydraulics.
2. Wiring and piping shown are general points-of-connection guides only and are not intended for a specific installation. Wiring and piping shown are for a
quick overview of system and are not in accordance with recognized standards.
3. All wiring must comply with applicable local and national codes.
4. All piping must follow standard piping techniques. Refer to Carrier System Design Manual or appropriate ASHRAE (American Society of Heating,
Refrigerating, and Air Conditioning Engineers) handbook for details.
5. Air separator required as close to chiller as possible (except primary/secondary systems).
a30-4867
a30-4868
Typical piping and wiring
Summary of Contents for Aquasnap 30RAP010
Page 14: ...14 a30 5349 Base unit dimensions 30RAP070 090...
Page 15: ...15 ACCESSORY STORAGE TANK FOR UNIT SIZES 010 015 a30 4879 Accessory dimensions...
Page 16: ...16 ACCESSORY STORAGE TANK FOR UNIT SIZES 018 030 a30 4880 Accessory dimensions cont...
Page 17: ...17 ACCESSORY STORAGE TANK FOR UNIT SIZES 035 060 a30 4881...
Page 60: ...60 600 760 a30 5264 Typical control wiring schematic...
Page 75: ......