46
30RAP ELECTRICAL DATA
DUAL POINT LOW SOUND AEROACOUSTIC™ FAN NO HYDRONIC PACKAGE
30RAP ELECTRICAL DATA
DUAL POINT OPTIONAL VALUE SOUND FAN NO HYDRONIC PACKAGE
LEGEND
NOTES:
1. Units are suitable for use on electrical systems where voltage supplied to the unit terminals
is not below or above the listed minimum and maximum limits. Maximum allowable phase
imbalance is: voltage, 2
%
; amps 10
%
.
2. All units/modules have dual point primary power connection. (Each unit/module requires its
own power supply.) Main power must be supplied from a field-supplied disconnect.
3. Cooler heater is wired into the control circuit so it is always operable as long as the power
supply disconnect is on, even if any safety device is open.
4. Power draw control circuits include cooler heaters (where used).
UNIT
30RAP
UNIT VOLTAGE
CIRCUIT 1
CIRCUIT 2
V-Hz
(3 Ph)
Supplied
MCA
MOCP
ICF
Rec
Fuse
Size
MCA
MOCP
ICF
Rec
Fuse
Size
Min
Max
070
208/230-3-60
187
254
155.6
200
425.8
175
181.4
225
451.6
200
380-3-60
342
418
96.0
125
249.5
110
110.5
125
264.0
125
460-3-60
414
506
75.0
100
220.4
90
87.4
110
232.8
100
575-3-60
518
632
65.3
80
167.7
80
77.0
100
179.4
90
0
8
0
208/230-3-60
187
254
202.7
250
438.6
225
181.4
225
451.6
200
380-3-60
342
418
110.8
125
216.2
125
110.5
125
264.0
125
460-3-60
414
506
92.5
110
213.6
100
87.4
110
232.8
100
575-3-60
518
632
79.1
90
163.2
90
77.0
100
179.4
90
090
208/230-3-60
187
254
217.4
250
487.6
250
181.4
225
451.6
200
380-3-60
342
418
133.9
150
287.4
150
110.5
125
264.0
125
460-3-60
414
506
104.8
125
250.2
125
87.4
110
232.8
100
575-3-60
518
632
91.4
110
193.8
100
77.0
100
179.4
90
UNIT
30RAP
UNIT VOLTAGE
CIRCUIT 1
CIRCUIT 2
V-Hz
(3 Ph)
Supplied
MCA
MOCP
ICF
Rec
Fuse
Size
MCA
MOCP
ICF
Rec
Fuse
Size
Min
Max
070
208/230-3-60
187
254
158.6
200
428.8
175
181.4
225
451.6
200
380-3-60
342
418
96.0
125
249.5
110
110.5
125
264.0
125
460-3-60
414
506
77.0
100
222.4
90
87.4
110
232.8
100
575-3-60
518
632
66.3
90
168.7
80
77.0
100
179.4
90
0
8
0
208/230-3-60
187
254
206.3
250
442.2
225
181.4
225
451.6
200
380-3-60
342
418
110.8
125
216.2
125
110.5
125
264.0
125
460-3-60
414
506
94.9
110
216.0
110
87.4
110
232.8
100
575-3-60
518
632
80.3
100
164.4
90
77.0
100
179.4
90
090
208/230-3-60
187
254
221.0
250
491.2
250
181.4
225
451.6
200
380-3-60
342
418
133.9
150
287.4
150
110.5
125
264.0
125
460-3-60
414
506
107.2
125
252.6
125
87.4
110
232.8
100
575-3-60
518
632
92.6
110
195.0
100
77.0
100
179.4
90
ICF
—
Instantaneous Current Flow
MCA
—
Minimum Circuit Amps
MOCP —
Maximum Overcurrent Protection
Electrical data (cont)
Summary of Contents for Aquasnap 30RAP010
Page 14: ...14 a30 5349 Base unit dimensions 30RAP070 090...
Page 15: ...15 ACCESSORY STORAGE TANK FOR UNIT SIZES 010 015 a30 4879 Accessory dimensions...
Page 16: ...16 ACCESSORY STORAGE TANK FOR UNIT SIZES 018 030 a30 4880 Accessory dimensions cont...
Page 17: ...17 ACCESSORY STORAGE TANK FOR UNIT SIZES 035 060 a30 4881...
Page 60: ...60 600 760 a30 5264 Typical control wiring schematic...
Page 75: ......