Page 26
Abnormal Call
Hangup Detection
Sets the interval between checks of the remote end‟s abnormal hangup, with the
default value of 0 (feature disabled), calculated by s. It is suggested to set to 10s if
this feature is necessary to be used.
Server Status
Detection
The interval of sending a heartbeat packet to detect the master registrar server
status, with the default value of 0 (feature disabled), calculated by s. It is suggested
to set to 15s if this feature is necessary to be used.
Available Port
Negotiation
When this feature is enabled, the gateway will send messages to the preset
negotiation server (e.g. VOS server) to let it know the number of available ports on
the gateway. By default this feature is disabled.
Cycle, Address
Cycle means how soon will the gateway send a message; Address indicates the
server address (e.g. VOS server).
Occasion to Reply
183
Sets the occasion to reply the 183 message. Two options including: Immediately
and After ringing, with the default value of
Immediately
.
Occasion to Reply
200 Ok
Sets the occasion to reply 200 OK. Two options including: After pickup and After
ringing, with the default value of
After pickup
.
3.4.3 SIP Station
A SIP terminal can be registered to the gateway to become a SIP station. Tick the option of
„
SIP
Station Supported
‟ on
3.4.2 SIP Compatibility
interface, and you will see the item SIP Station on
the VoIP Settings menu. Click
„
SIP Station
‟ to go into the SIP Station interface. By default, there is
no available SIP station. See Figure 3-18 below.
Figure 3-18 SIP Station Setting Interface
Click
Add New
to add SIP stations manually. See Figure 3-19. You can configure basic SIP
station information on this interface. The bound port to a SIP station must be a wireless port and
unique. The username must be the same as that used to register the SIP terminal to the gateway.
S
MG
Series
Wireless
Gateway
User
Manual
(Version
1.9.0)