Label 80777-09
Requirements
These applicators are FM approved when the product
setup is configured to drawings shown on the following
pages. This product is approved for use only with non-
flammable water-based materials when the materials
meet the FM definition for a waterbased spray material*.
It is the end users’ responsibility to insure the material that
is sprayed meets this requirement.
Label 80777-10
* FM 7260 waterbased spray material - a material that
does not sustain burning when tested in accordance with
ASTM D 4206.
Atex Requirements
This product provides an indirect charge to water based
materials that will improve the transfer efficiency over
non-electrostatic products. Because it is In-Direct charge,
the fluid delivery system may be completely grounded
from the source all the way to the applicator. Because this
product uses water based materials only, there may be no
requirement for an ATEX approval. As long as the material
being used meets the flammability definition as stated in
EN 50059: 1991**, there is no hazardous area that must
ATEX REQUIREMENTS
FM REQUIREMENTS
be zoned around the applicator. No ATEX approval is
required. It is the end users responsibility to insure all of
these conditions are met.
**EN 50059: 1991 Definition of non-flammable
spraying material
The material applied by means of electrostatic hand held
spraying equipment and which cannot be ignited, when in
any mixture with air, by an energy source less than 500 mJ.
By Ransburg
®
AH-17-02-R1 (10/2019)
9 / 55
www.carlisleft.com
ATEX
EN