2. All objects inside spray area must be grounded - refer-
ence EN 50176 and/or NFPA-33. Resistance to earth
ground must be less than 1 meg Ohm.
3. Flammable liquids must be contained in approved
metalic grounded containers.
1. Ensure there is a true earth ground connection available.
Connect the fluid source and air hose ground to this
connection.
Interlocks Required
Interlock the solvent supply with the main supply air to
the applicator. When solvent is On, main supply air to the
applicator is Off. Interlocks are user supplied.
INSTALLATION
2. Turn off power.
3. Connect fluid hose.
WA R N I N G
!
WA R N I N G
!
The solvent supply must be interlocked with
applicator supply air.
Both the fluid source and the air hose ground must be
connected to true earth ground.