2. Disconnect air to applicator.
OR...
FLUSHING / COLOR
CHANGE PROCEDURE
1. Turn off electrostatics.
WA R N I N G
!
The solvent supply must be interlocked with the
applicator supply air.
FLUID NOZZLE / AIR CAP
The fluid nozzle and air cap must be selected according
to the application. The following charts show the nozzles
and air caps available for the Ransflex.
3. Discharge fluid into appropriate earth grounded
metal container
4. Load next color, solvent flush and/or remove applicator
from installation as required.
CAUTION
!
Nozzles from previous Ransburg design are not
compatable with the Ransflex design. Use of these
nozzles could cause equipment malfunction and
possible damage.
AH-17-02-R1 (10/2019)
23 / 55
www.carlisleft.com
OPERATION