Daily (or at start of each shift)
• Verify that ALL solvent safety containers are grounded!
• Check within 6m (20-ft.) of the point of operation (of
the applicator) and remove or ground ALL loose or
ungrounded objects.
• Inspect work holders for accumulated coating materials
(and remove such accumulations).
Bi-Yearly
• Check air hose resistance. If resistance is greater than
.5 M
W
the hose should be replaced.
• Check that atomizer assembly is clean and undamaged.
• Straighten the applicator electrode if necessary.
• Clean the fluid filter, if used.
Air Cap Removal
1. Remove retaining ring and air cap.
WA R N I N G
!
NOTE
Standard electrode is "snap back" spray wire
electrode.
It is the end users responsibility to insure the .5 M
W
to ground condition is met.
AH-17-02-R1 (10/2019)
27 / 55