13. Adjust fan pattern as required.
NOTE
14. Adjust fluid flow.
NOTE
It is recommended fluid flow be controlled by
the supply regulator. This adjustment should only be
used for fine adjustments.
15. Adjust compensation valve with small driver.
NOTE
The compensation valve adjustment is used to
adjust fan and atomization pressure at the same time
when the pressure to run the turbine is higher than the
atomization fan pressure desired.
AH-17-02-R1 (10/2019)
22 / 55
www.carlisleft.com
OPERATION