INSTALLATION
Fluid Hose Recommendation
Ransburg recommends using a 80303-XX Fluid Hose
Assembly. This assembly is made to specifically fit the
fluid fitting size engineered into the applicator. This hose
is available from your authorized Ransburg distributor.
Available hose lengths are listed in "Accessories" in the
"Parts Identification" section of this manual.
Filters
1. Install an air filter assembly on the outlet of the main air
regulator. The filter should be 5 micron with a maximum
working pressure of at least 100 psig (6.9 bar). For
Class 3 air quality, which is a 5 micron size and has a
dew point of -4°F (-20°C), the relative humidity (RH) of
the air should be 5%.
2. Ransburg recommends that a fluid filter be installed at the
output of the fluid supply (pressure pot, pump, circulating
system, etc.). It is the end user's responsibility to install
the proper filter that meets their system's requirements.
81465 RANSFLEX INDIRECT
CHARGE WATERBORNE
INSTALLATION
GENERAL INSTALLATION
REQUIREMENTS
1. Operator must make skin contact with handle of
applicator. If gloves are required use either gloves
with palm and finger cut out or conductive gloves. See
accessory pages for conductive gloves.
WA R N I N G
!
Air Hose
Any user installed fluid hose used must be rated
for (100 psig) 6.9 bar working pressure minimum.
For proper safe function of the applicator, the
80558-XX Air Hose Assembly must be used (either
standard or quick disconnect style).
WA R N I N G
!
CAUTION
!
The user
MUST
read and be familiar with the
"Safety" section of this manual.
This hand held device is intended to be used by
trained personnel ONLY.
This manual
MUST
be read and thoroughly
understood by
ALL
personnel who operate, clean, or
maintain this equipment! Special care should be taken
to ensure that the warnings and requirements for
operating and servicing safely are followed. The user
should be aware of and adhere to
ALL
local building
and fire codes and ordinances as well as NFPA,
OSHA, and all related country safety codes prior to
installing, operating, and/or servicing this equipment.
Personnel
MUST
be
GROUNDED
to prevent a
shock or spark during electrostatic operation.
Install and route the hoses so they are
NOT
exposed to temperatures in excess of 120
°
F (49°
C) and so that all hose bends are
NO LESS
than a
6-inch (15cm) radius. Failure to comply with these
parameters could cause equipment malfunction that
might create
HAZARDOUS CONDITIONS!
WA R N I N G
!
This applicator is for use with non-flamable water base
materials only. The material when atomized cannot be
ignited by an energy greater than 500mJ. Consult your paint
supplier to insure your material meets these reqirements.
Material that will not sustain burning when tested in
accordance with ASTM D 4206.
AH-17-02-R1 (10/2019)
17 / 55
www.carlisleft.com
INSTALLATION
EN