![background image](http://html.mh-extra.com/html/canon/imageformula-dr-1210c/imageformula-dr-1210c_service-manual_62930107.webp)
COPYRIGHT © 2006 CANON ELECTRONICS INC. CANON DR-1210C FIRST EDITION FEB. 2006
A-5
Appendix
4) Press the two areas around section A on
the operation panel
{
1
downward and
unhook the fitting parts inside. Turning the
operation panel, further unhook the fitting
parts inside, then remove the operation
panel. The cable connected to the opera-
tion panel is also disconnected at the
same time.
Figure A-304
5) Remove the 2 screws
{
1
. Lifting up end of
the flatbed cover
{
2
and unhooking the fit-
ting parts inside, remove the flatbed cover.
Note:
The fitting parts inside may be broken in
the procedures to remove the flatbed
cover. It is not a problem, however, be-
cause this is for discarding.
Figure A-305
6) Remove the 2 screws
{
1
and cable cover
{
2
. Then disconnect the cable
{
3
of the
reading unit.
Figure A-306