3-12
COPYRIGHT © 2006 CANON ELECTRONICS INC. CANON DR-1210C FIRST EDITION FEB. 2006
CHAPTER 3 DISASSEMBLY & ASSEMBLY
6) Draw the cable
{
1
out of the groove in the
cover. Remove the 3 connectors
{
2
and
remove the ADF PCB
{
3
(with ADF ca-
ble).
Note:
Take care not to break the cables and
damage the wire insulations.
Figure 3-224
Note:
For reassembling, hold the ground
cable first, then hold the hinge mounting
plate. In addition, insert the 2 sensor
cables in the correct connectors. The
red cable for document sensor must be
inserted in JDS1 (white) and the black
one for ADF sensor, in JDES1 (black).
8. Feed Unit/Feed Motor
Note:
The motor can be removed when dis-
assembling the feed unit.
1) Remove the ADF bottom cover.
2) Remove the hinge (left).
3) Remove the hinge mounting plate.
4) Remove the ADF PCB.
5) Draw the cables
{
1
out of the groove in
the cover one by one. Then, remove the
screw
{
2
(M3
×
L6, self-tapping).
Note:
Take care not to break the cables and
damage the wire insulations.
Figure 3-225