![background image](http://html.mh-extra.com/html/canon/imageformula-dr-1210c/imageformula-dr-1210c_service-manual_62930075.webp)
COPYRIGHT © 2006 CANON ELECTRONICS INC. CANON DR-1210C FIRST EDITION FEB. 2006
4-11
CHAPTER 4 INSTALLATION & MAINTENANCE
III. MAINTENANCE
1. User Maintenance
Refer to user manual for details.
1) List
No. Location/Part
Item
Details
1
Main body
Cleaning
Wipe the surfaces with a cloth dipped into
water and wrung tightly, then wipe dry.
2
Feed path
Cleaning
Using a blower, etc., remove dust and paper
powder from the document feed opening and
inside of the feeder.
3 Reading
glass
Cleaning
4 Pressure
board Cleaning
Wipe with a clean and dry cloth. See section
2).
5 Roller
unit
Cleaning,
replacement
6 Separation
pad Cleaning,
replacement
Remove the roller unit from the main body.
Wipe the surfaces with a cloth dipped into
water and wrung tightly, then wipe dry. The
roller unit and the separation pad are con-
sumable parts and the roller unit should be
replaced after an expected life of 100,000
sheets and the separation pad, 50,000 sheets.
See section 3).
Table 4-301
2) Reading glass and pressure board
Where to clean is as follows.
Reading glass
For feeder
For flatbed
Figure 4-301
Pressure board
Figure 4-302