COPYRIGHT © 2006 CANON ELECTRONICS INC. CANON DR-1210C FIRST EDITION FEB. 2006
5-7
CHAPTER 5 TROUBLESHOOTING
III. OPERATION TROUBLESHOOTING
1. No Power
The power indicator and display do not light.
The fluorescent lamp of the reading unit does not light.
Cause/Faulty
location
Step Check
item Result Action
Connection of power
cord
1
Are the power cord and the
AC adapter connected?
NO
Connect properly.
AC power supply
voltage
2 Is the specified voltage
supplied to the power out-
let?
NO
Explain user that the
trouble is not with this
machine.
Power cord,
AC adapter
3 Is the problem solved by
replacing the power cord
and the AC adapter?
YES
End.
YES Properly connect the
operation PCB. Or re-
place the operation
panel.
Operation PCB,
Flatbed assembly
4
Does the fluorescent lamp
of the reading unit work?
NO Faulty flatbed assem-
bly. Replace the main
body.
Table 5-301