Chapter 7
7-34
65th-96th characters of Detailed Communication Error Information are shown.
F-7-54
97th-128th characters of Detailed Communication Error Information are shown.
F-7-55
- Use
and
keys to move among Screen and Screen. (Detailed Communication Error Information can be made with maximum 128 characters, however, even
if the information is made up with 1 to 96 characters, all Screens are still displayed.)
- Press
key to exit the Detailed Communication Error Information screen and go back to the Communication Error Information screen.
* If Detailed Communication Error Information does not exist, the screen below will appear.
F-7-56
- Press
key to exit the Detailed Communication Error Information screen and go back to the Communication Error Information screen.
5) Initializing the e-RDS setting [ERDS-DAT]
Usually, the setup is not necessary.
Use this procedure when you want to reset the e-RDS settings to the factory default.
(1) In service mode, referring to the "Service Mode Menu Tree", go to [ERDS-DAT] menu using
key and
key.
F-7-57
(2) Choose between YES/NO using
and
keys, and press [OK] key to set.
F-7-58
- Press [OK] key, and "=" will appear and the initializing process will begin.
[NO]: Do not initialize the e-RDS setting. Default value is [NO].
[YES]: Initialize the e-RDS setting.
6) Displaying the CA Certificate Information [VALIDITY]
For the secure communication between the device (e-RDS) and the UGW, an authentication technology from a certification authority is used. A license has been
issued from the certification authority. For this reason, the devices are shipped with the CA (Certificate Authority) certificate enabled in advance to prove the license
obtained.
Therefore, usually, the setup is not necessary.
To confirm that this CA certificate is valid or how long it will be valid, you can display the expiration date of the CA certificate information.
(1) In service mode, referring to the "Service Mode Menu Tree", go to [VALIDITY] menu using
key and
key.
F-7-59
(2) Press
key, and the expiration date of the CA certificate will be displayed.
F-7-60
X X X X X X X X X X X X X X X X
X X X X X X X X X X X X X X X X
X X X X X X X X X X X X X X X X
X X X X X X X X X X X X X X X X
N O
E R R O R
D E T A I
L
N O
E
- R D S
D A T
= Y E S
E
- R D S
D A T
V A L I
D I
T Y
C A
- C E R T I
F I
C A T E
Y Y Y Y /
M M /
D D
V A L I
D I
T Y
Summary of Contents for image Prograf iPF780 Series
Page 1: ...Mar 27 2014 Service Manual iPF780 760 750 series iPF785...
Page 9: ...Chapter 1 PRODUCT DESCRIPTION...
Page 57: ...Chapter 2 TECHNICAL REFERENCE...
Page 117: ...Chapter 3 INSTALLATION...
Page 125: ...Chapter 4 DISASSEMBLY REASSEMBLY...
Page 175: ...Chapter 4 4 49 2 Shaft Cleaner 1 F 4 97 1 1...
Page 176: ...Chapter 4 4 50 3 Upper Cover Hinge Catch 1 Roll Cover Slide Guide 2 F 4 98 2 1...
Page 179: ...Chapter 5 MAINTENANCE...
Page 186: ...Chapter 6 TROUBLESHOOTING...
Page 212: ...Chapter 7 SERVICE MODE...
Page 267: ...Mar 19 2014 PARTS CATALOG iPF786 785 781 780 765 760 755 750...
Page 301: ...2 25 FIGURE 10 PLATEN GUIDE UNIT 1 3 6 2 8 4 5 10 10 10 9 9 11...