6.2.4 Sevice Call Table
6.2.4.1 Service Call Errors
0031-2607
*: Codes correspond to the numbers shown on the DISPLAY in the service mode.
Code*
Description
Action
E141-4046
Number of recovery rotations reaching
50,000 or more
Replace the purge unit, and then clear the parts counter in the service mode.
E144-4047
Number of carrriage scan operation is full Replace the tube unit, and then clear the parts counter in the service mode.
E144-4048
Printhead ink filling failure
Replace the printhead.
E146-4001
Waste ink recovery count error
Replace the platen duct or mist fan or mist filter or suction fan, and then clear the parts
counter in the service mode.
(Confirm the parts reached to the exchange value by the service mode or PRINT INF.)
E161-403E
Abnormal temperature rise in left printhead Replace the left printhead.
E161-403F
Abnormal temperature rise in right
printhead
Replace the right printhead.
E161-4050
Printhead ink filling non-ejection detection
error (when installing the printer or
replacing the printhead)
Replace the printhead.
E194-404A
Non-discharging nozzle count error
Replace the head management sensor unit, and then clear the parts counter in the service
mode.
E196-4040
Checksum error (when executing the
firmware update)
Execute firmware update or replace the main controller PCB.
E196-4041
Flash memory erase error (when executing
the firmware update)
Execute firmware update or replace the main controller PCB.
E196-4042
Flash memory write error (when executing
the firmware update)
Execute firmware update or replace the main controller PCB.
E196-4043
Memory error (when executing the
firmware update)
Execute firmware update or replace the main controller PCB.
E196-4044
Firmware size error (when executing the
firmware update)
Execute firmware update or replace the main controller PCB.
E196-4045
EEPROM read/write error (controller part) Replace the main controller PCB.
E196-4049
Firmware data error (when executing the
firmware update)
Execute firmware update or replace the main controller PCB.
E196-404C
Serial number mismatch between main
controller PCB and maintenance cartridge
ROM PCB.
Execute PCB replacement mode or replace the main controller PCB.
E196-404D
Machine ID mismatch between main
controller PCB and maintenance cartridge
ROM PCB.
Execute PCB replacement mode or replace the main controller PCB.
E196-404E
EEPROM read/write error (engine part)
Replace the main controller PCB.
E198-401C
RTC error
Replace the lithium battery or replace the main controller PCB.
E198-401D
RTC low battery error
Replace the lithium battery or replace the main controller PCB.
E198-401E
RTC clock stop
Replace the lithium battery or replace the main controller PCB.
E199-404B
Temperature/humidity sensor connector
out of position
Check the temperature/humidity sensor connector or replace the sensor.
E602-401A
HDD read/write error (HDD failure)
Replace the HDD unit.
E602-401B
HDD connection error
Check the HDD connector or replace the HDD.
E602-405A
HDD size error
Replace the HDD unit.
E602-405B
HDD model error
Replace the HDD unit.
Summary of Contents for image Prograf iPF780 Series
Page 1: ...Mar 27 2014 Service Manual iPF780 760 750 series iPF785...
Page 9: ...Chapter 1 PRODUCT DESCRIPTION...
Page 57: ...Chapter 2 TECHNICAL REFERENCE...
Page 117: ...Chapter 3 INSTALLATION...
Page 125: ...Chapter 4 DISASSEMBLY REASSEMBLY...
Page 175: ...Chapter 4 4 49 2 Shaft Cleaner 1 F 4 97 1 1...
Page 176: ...Chapter 4 4 50 3 Upper Cover Hinge Catch 1 Roll Cover Slide Guide 2 F 4 98 2 1...
Page 179: ...Chapter 5 MAINTENANCE...
Page 186: ...Chapter 6 TROUBLESHOOTING...
Page 212: ...Chapter 7 SERVICE MODE...
Page 267: ...Mar 19 2014 PARTS CATALOG iPF786 785 781 780 765 760 755 750...
Page 301: ...2 25 FIGURE 10 PLATEN GUIDE UNIT 1 3 6 2 8 4 5 10 10 10 9 9 11...
Page 326: ......