SERVICE MODE:
- COPIER> OPTION> BODY> FUZZY
(enabling/disabling fuzzy control)
0: enables fuzzy control (default)
1: low humidity mode (the separation current is lower that standard)
2: normal humidity mode
3: high humidity environment mode (the separation current is higher than standard)
If set to '1' thorough '3', the control will be independent of the environment sensor.
7.9.1.3 Correcting the Output upon Detection of Leakage
0010-8078
iR7105 / iR7095 / iR7086
If leakage is detected, the separation output will be supplied at a lowered output level.
F-7-45
SERVICE MODE:
- COPIER> OPTION> BODY> SP-MODE
(enabling/disabling separation current output correction control)
0: standard mode (AC output is 10.0 kVpp, default)
1: low voltage mode (AC output is 9.0 kVpp; if error is frequent because of leakage)
7.9.1.4 Others
0010-8079
iR7105 / iR7095 / iR7086
SERVICE MODE:
- CODIER> ADJUST> HV-SP> SP-N1
(output adjustment for plain paper simplexing or 1st side of duplexing)
If the DC controller PCB has been replaced or the RAM on the DC controller has been initialized, enter the value indicated on the service label.
-
CODIER> ADJUST> HV-SP> SP-N2
(output adjustment for 2nd side of plain paper duplexing)
If the DC controller PCB has been replaced or the RAM on the DC controller has been initialized, enter the value indicated on the service label.
COPIER > OPTION > BODY > SP-MODE
Setting
Main power switchOFF/ON
If leakage current is detected,
a retry is made with a lowered
output level.
Low voltage mode
10.0 kvpp
8.5 kvpp
9.0 kvpp
8.5 kvpp
Leakage current is detected,
and a retry is made with a
lowered output level.
NG
E068 indication
Summary of Contents for 7086 Series
Page 1: ...Sep 7 2007 Service Manual iR7105 7095 7086 Series ...
Page 2: ......
Page 6: ......
Page 26: ...Contents ...
Page 27: ...Chapter 1 Introduction ...
Page 28: ......
Page 30: ......
Page 32: ...Chapter 1 1 2 Not all products are necessarily available in all sales areas ...
Page 55: ...Chapter 2 Installation ...
Page 56: ......
Page 150: ......
Page 151: ...Chapter 3 Basic Operation ...
Page 152: ......
Page 154: ......
Page 159: ...Chapter 4 Main Controller ...
Page 160: ......
Page 162: ......
Page 183: ...Chapter 5 Original Exposure System ...
Page 184: ......
Page 228: ......
Page 229: ...Chapter 6 Laser Exposure ...
Page 230: ......
Page 232: ......
Page 238: ...Chapter 6 6 6 F 6 7 1 Laser light 2 Laser shutter 1 2 1 2 2 1 ...
Page 240: ......
Page 241: ...Chapter 7 Image Formation ...
Page 242: ......
Page 246: ......
Page 294: ......
Page 295: ...Chapter 8 Pickup Feeding System ...
Page 296: ......
Page 300: ......
Page 353: ...Chapter 9 Fixing System ...
Page 354: ......
Page 378: ......
Page 379: ...Chapter 10 External and Controls ...
Page 380: ......
Page 384: ......
Page 394: ...Chapter 10 10 10 F 10 7 ...
Page 417: ...Chapter 11 MEAP ...
Page 418: ......
Page 420: ......
Page 466: ......
Page 467: ...Chapter 12 RDS ...
Page 468: ......
Page 470: ......
Page 479: ...Chapter 13 Maintenance and Inspection ...
Page 480: ......
Page 482: ......
Page 496: ......
Page 497: ...Chapter 14 Standards and Adjustments ...
Page 498: ......
Page 526: ......
Page 527: ...Chapter 15 Correcting Faulty Images ...
Page 528: ......
Page 530: ......
Page 560: ......
Page 561: ...Chapter 16 Self Diagnosis ...
Page 562: ......
Page 564: ......
Page 584: ......
Page 585: ...Chapter 17 Service Mode ...
Page 586: ......
Page 588: ...Contents 17 8 1 1 COPIER Items 17 94 ...
Page 688: ......
Page 689: ...Chapter 18 Upgrading ...
Page 690: ......
Page 692: ......
Page 696: ...Chapter 18 18 4 ...
Page 713: ...Chapter 18 18 22 formatting and download the system software once again ...
Page 726: ...Chapter 19 Service Tools ...
Page 727: ......
Page 729: ......
Page 733: ......
Page 734: ...Sep 7 2007 ...
Page 735: ......