2
2
2-17
2-17
Technical Explanation > Original Exposure and Feed System > Controls > Dust Detection Preventive Process
Technical Explanation > Original Exposure and Feed System > Controls > Dust Detection Preventive Process
■
Dust Detection Preventive Process
The contact image sensor (CIS) detects the reflected light from the ADF reading glass and
platen guide surface (at the read position) to judge presence or absence of dust.
This process is performed when the power is turned on or each time a job is completed.
The dust detection process is performed at three positions (A, B, and C) as follows regardless
of whether there is dust:
1) The dust detection process is performed at position A.
2) The dust detection position moves to position B to perform the dust detection process
there.
3) The dust detection position moves to position C to perform the dust detection process
there.
4-a) The dust-free position is determined as the original read position in the order of priority (A
> B > C).
4-b) If dust is detected at all of positions A, B, and C, position A is determined as the original
read position.
0.5mm
0.5mm
A B C
Contact image sensor unit
Platen guide
ADF reading glass
Lens
Position
Description
A
Reference position for read
B
About 0.5 mm to the right of the reference position A
C
About 1.0 mm to the right of the reference position A
Note:
When dust has been detected at all of positions A, B, and C, setting an original on the
ADF will show a message that prompts the user to clean the glass surface.
F-2-28
T-2-8
Summary of Contents for 1730
Page 12: ...Update Firmware XXV Volume Control XXV Backup Data XXVI ...
Page 17: ...1 1 Product Overview Product Overview Product Lineup Features Specifications Parts Name ...
Page 235: ...7 7 Error Code Error Code Overview Error Code Jam Code Alarm Code ...
Page 250: ...8 8 Service Mode Service Mode Outline Details of Service Mode ...
Page 333: ... Service Tools General Timing Chart General Circuit Diagram List of User Mode Appendix ...