8
8
8-47
8-47
Service Mode > Details of Service Mode > #REPORT > Configuration
Service Mode > Details of Service Mode > #REPORT > Configuration
#E-RDS
■
Configuration
Settings related to e-RDS are described below.
Item
Default
Setting range
Description
E-RDS
SWITCH
0
0 or 1
e-RDS OFF/ON setting (0:OFF / 1:ON)When
used (ON), the counter information and error
information are sent to UGW.Default: 0 (OFF)
RGW-
ADDRESS
URL of UGW Character string
length:129byte
(including NULL,
one-byte codes only)
URL of UGWDefault: URL of actual
UGWCharacter string length: 129 bytes (including
NULL, one-byte codes only)
RGW-PORT 443
1-65535
Port No. of UGW
Setting range: 1 to 65535
CNT-DATE
Setting of the date of sending the counter
information to the server (Valid after input of
license).
Set the start date of the schedule to send the
counter information to the server using a third
party expansion function of E-RDS.
Refer to the user mode date setting.
(12 digits: YYYYMMDDHHMM)
YYYY: Year MM: Month DD: Day
HH: Hour MM: Minute
CNT-INTV
24
1-168 (on a weekly
basis)
Setting of the interval of sending the counter
information to the server (Valid after input of
license).
Set the interval of sending the counter information
to the server using a third party expansion function
of E-RDS.
COM-TEST
Execution of communication test An attempt
is made to connect to UGW, judges whether
connection is successful, and displays "COM-
TEST OK" or "COMTEST NG" as the judgment
result.
COM-LOG
Details of communication test result. The log of
errors in communication with UGW is displayed.
The error information includes the error occurrence
time, error code, and details of the error.Maximum
log count: 5Error information length: Max. 128
characters (excluding NULL)
T-8-56
#REPORT
■
Configuration
The table below lists the kinds of reports that are supported.
Item
Explanation
SERVICE DATA LIST
"Service mode service soft switch output (SSSW, MENU, NUMERIC
Param., SPECIAL, NCU, SCAN, PRINT, SYSTEM, ROM,
start date)"
SYSTEM DATA LIST
"Service mode service soft switch output (SSSW, MENU, NUMERIC
Param., SPECIAL, NCU, SCAN, PRINT, SYSTEM, ROM,
start date) System dump list output"
SYSTEM DUMP LIST
Transmission count, reception count, record chart count, error count
and other outputs
COUNTER LIST
Counter output
ERROR LOG LIST
Jam and error history output
SPEC LIST
Type setting, print speed, memory size, ROM indication, adjustment
data and other outputs
SERVICE LABEL
Not used.
ERDS COM LOG LIST
Output of communication error log information related to e-RDS
T-8-57
Summary of Contents for 1730
Page 12: ...Update Firmware XXV Volume Control XXV Backup Data XXVI ...
Page 17: ...1 1 Product Overview Product Overview Product Lineup Features Specifications Parts Name ...
Page 235: ...7 7 Error Code Error Code Overview Error Code Jam Code Alarm Code ...
Page 250: ...8 8 Service Mode Service Mode Outline Details of Service Mode ...
Page 333: ... Service Tools General Timing Chart General Circuit Diagram List of User Mode Appendix ...