8
8
8-18
8-18
Service Mode > Details of Service Mode > #NUMERIC > Details
Service Mode > Details of Service Mode > #NUMERIC > Details
●
023:CNG detention level for fax/tel switchover
Use it to set the CNG detention level for a fax/tel switchover.
●
024:pseudo RBT transmission level at time of fax/tel switchover
Use it to set the pseudo transmission level for a fax/tel switchover.
●
025: Answering machine connection function signal detection time
Sets the signal detection time for the answering machine connection function operation.
When the answering machine connection function is operating, if the function does not
operate normally because the fax does not detect CNG signal sent from the line, raise this
parameter to increase the signal detection time.
●
027:V.21 low-speed flag preamble identification length
Use it to detect the time of detection after which command analysis is started after
detecting V.21 low-speed command preambles continuously for a specific period of time.
●
051: Hook detection threshold value
The time until it is judged as Off-hook can be set.
●
053: To set the number of DTMF calls at FAX remote reception
The number of digits to detect remote reception ID when answering by the answering phone
can be set.
Default: 2
●
055: Acquisition period of environmental log data
You can change data acquisition cycle of environment log.
●
056 - 061: Count type select
Use it to confirm the count type indicated on the Counter Check screen, which appears in
response to a press on the Counter key.
When ‘0’ is selected, count type will not be indicated.
056: Use it to indicate the type of software counter 1 of the control panel. The type of soft
counter 1 cannot be changed.
057: Use it to change the type of soft counter 2* of the control panel to suit the needs of the
user.
058: Use it to change the type of soft counter 3* of the control panel to suit the needs of the
user.
059: Use it to change the type of soft counter 4* of the control panel to suit the needs of the
user.
060: Use it to change the type of soft counter 5* of the control panel to suit the needs of the
user.
061: Use it to change the type of soft counter 6* of the control panel to suit the needs of the
user.
*:The default type settings of soft counter is different from models.
<Soft Counter Specifications>
The soft counters are classified a follows in terms of input numbers:
100s: total
200s: copy
300s: print
400s: copy + print
500s: scan
700s: received file print
800s: report pint
900s: transmitted scan
Guide to the Table
- 1:Count sheets of all sizes by one.
- 2:Count sheets of the large size by two.
- Bk:Black mono
- C:Full color (Scan only)
- S:Small size (A4/LTR or smaller)
- L: Large size (Larger than A4/LTR)
Since this machine is an A4/LTR model, a counter for large size (B4 and larger) does not
operate although it exists. In addition, since it is also a B&W machine, only a color scan
counter exists. Therefore, many similar count-up specifications exist. For example, Total1,
Total2, Total(S), Total(Bk1), Total(Bk2) and Total(Bk/S) all mean the same with this machine.
Any counter can be used.
Summary of Contents for 1730
Page 12: ...Update Firmware XXV Volume Control XXV Backup Data XXVI ...
Page 17: ...1 1 Product Overview Product Overview Product Lineup Features Specifications Parts Name ...
Page 235: ...7 7 Error Code Error Code Overview Error Code Jam Code Alarm Code ...
Page 250: ...8 8 Service Mode Service Mode Outline Details of Service Mode ...
Page 333: ... Service Tools General Timing Chart General Circuit Diagram List of User Mode Appendix ...