8
8
8-11
8-11
Service Mode > Details of Service Mode > #SSSW > Details
Service Mode > Details of Service Mode > #SSSW > Details
Detailed Discussions of Bit 2
If ANSam signal is not received during transmission, select whether to use the V.8 protocol
when the other fax machine declares the V.8 protocol in DIS signal. If NO is selected, the CI
signal is not transmitted and the V.8 protocol is not used even if the DIS that specifies the V.8
protocol is received.
The V.8 late start is not executed during manual transmission regardless of this setting.
Detailed Discussions of Bit 3
Select whether to declare the V.8 protocol in DIS signal for reception. If NO is selected, the V.8
protocol cannot be used because it is not declared in DIS signal.
The V.8 late start is not executed during manual reception regardless of this setting.
Detailed Discussions of Bit 4
Select whether the receiver falls back during V.34 reception. If 'Prohibit' is selected, the
receiver does not fall back.
Detailed Discussions of Bit 5
Select whether the transmitter falls beck during V.34 transmission. If 'Prohibit' is selected, teh
transmitter does not fall back.
●
SSSW-SW30
List of Functions
Bit
Function
1
0
0
not used
-
-
1
not used
-
-
2
not used
-
-
3
not used
-
-
4
not used
-
-
5
New dial tone detection method
Detect with the new
method.
Detect with the
existing method.
6
not used
-
-
7
not used
-
-
Detailed Discussions of Bit 5
When "Detect with the new method" is selected, tone is detected for 3.5 seconds before call
origination in order to discriminate between dial tone and voice. If dial tone is detected and
the time since line seizure is 3.5 seconds or longer, call origination takes place immediately. If
the time since line seizure is less than 3.5 seconds,
call origination takes place after waiting for 1 second. (If the time since line seizure reaches
3.5 seconds during the 1-second waiting period, call origination takes place immediately. By
default, "Detect with a new method" is assigned for this SW.
T-8-20
●
SSSW-SW32
List of Functions
Bit
Function
1
0
0
not used
-
-
1
not used
-
-
2
not used
-
-
3
not used
-
-
4
not used
-
-
5
NCU version
NCU2002
NCU2004
6
not used
-
-
7
not used
-
-
Detailed Discussions of Bit 5
NCU (Network Control Unit) version can be selected.
●
SSSW-SW33
List of Functions
Bit
Function
1
0
0
count B4 (Print) as large size
Yes
No
1
not used
-
-
2
count B4 (Scan) as large size
Yes
No
3
not used
-
-
4
not used
-
-
5
Toner cartridge replacement counter display
Yes
No
6
not used
-
-
7
not used
-
-
Detailed Discussions of Bit 0
Use it to specify whether B4 paper (Print) should be counted as large-size paper.
If 'yes' is selected, B4 paper will be counted as large-size paper.
If 'no' is selected, on the other hand, B4 paper will be counted as small-size paper.
Detailed Discussions of Bit 2
Use it to specify whether B4 paper (Scan) should be counted as large-size paper.
If 'yes' is selected, B4 paper will be counted as large-size paper.
If 'no' is selected, on the other hand, B4 paper will be counted as small-size paper.
T-8-21
T-8-22
Summary of Contents for 1730
Page 12: ...Update Firmware XXV Volume Control XXV Backup Data XXVI ...
Page 17: ...1 1 Product Overview Product Overview Product Lineup Features Specifications Parts Name ...
Page 235: ...7 7 Error Code Error Code Overview Error Code Jam Code Alarm Code ...
Page 250: ...8 8 Service Mode Service Mode Outline Details of Service Mode ...
Page 333: ... Service Tools General Timing Chart General Circuit Diagram List of User Mode Appendix ...