Section 8. Operation
381
<file
is_dir="false"
path="CPU:lights-web.cr1"
last_write="yyyy-mm-ddThh:mm:ss.xxx"
size="16994"
run_now="true"
run_on_power_up="true"
read_only="false"
paused="false"/>
</ListFilesResponse>
JSON Response
When
json
is entered in the
ListFiles
format
parameter, the response will be
formated as
CSIJSON
(p. 68).
Following is an example response.
{
"files": [
{
"path": "CPU:",
"is_dir": true,
"size": 50000,
"last_write": "yyyy-mm-ddThh:mm:ss.xxx",
"run_now": false,
"run_on_power_up": false,
"read_only": false,
"paused": false
},
{
"path": "CPU:lights-web.cr1",
"is_dir": false,
"size": 16994,
"last_write": "yyyy-mm-ddThh:mm:ss.xxx",
"run_now": true,
"run_on_power_up": true,
"read_only": false,
"paused": false
},
]
}
8.6.3.7.4 NewestFile Command
NewestFile
allows a web client to request a file, such as a program or image, from
the host CR800. If a wildcard (*) is included in the expression, the most recent in
a set of files whose names match the expression is returned. For instance, a web
page may be designed to show the newest image taken by a camera attached to the
CR800.
NewestFile
takes the form:
http://192.168.13.154/?command=NewestFile&expr=drive:filename.ex
t
Where
filename
can be a wildcard (*).
NewestFile
requires a minimum
.csipasswd
access level of
3
(read only) for all
files except program files. Program files require access level
1
(all access
allowed).
Summary of Contents for CR850
Page 2: ......
Page 4: ......
Page 6: ......
Page 26: ...Table of Contents 26...
Page 30: ...Section 2 Cautionary Statements 30...
Page 32: ...Section 3 Initial Inspection 32...
Page 35: ...Section 4 Quickstart Tutorial 35 Figure 2 Wiring panel...
Page 55: ...Section 4 Quickstart Tutorial 55 Figure 24 PC200W View data utility...
Page 78: ...Section 5 System Overview 78...
Page 80: ...Section 6 CR800 Specifications 80...
Page 267: ...Section 7 Installation 267 Figure 84 Running average signal attenuation...
Page 268: ...Section 7 Installation 268...
Page 384: ...Section 8 Operation 384 Figure 113 Using the keyboard display...
Page 387: ...Section 8 Operation 387 Figure 116 Real time custom...
Page 388: ...Section 8 Operation 388 8 8 1 3 Final Storage Tables Figure 117 Final storage tables...
Page 389: ...Section 8 Operation 389 8 8 2 Run Stop Program Figure 118 Run Stop Program...
Page 390: ...Section 8 Operation 390 8 8 3 File Display Figure 119 File display...
Page 396: ...Section 8 Operation 396...
Page 402: ...Section 9 Maintenance 402...
Page 450: ...Section 11 Glossary 450...
Page 504: ...Appendix A CRBasic Programming Instructions 504...
Page 526: ...Appendix B Status Table and Settings 526...
Page 530: ...Appendix C Serial Port Pinouts 530...
Page 536: ...Appendix E FP2 Data Format 536...
Page 550: ...Appendix F Other Campbell Scientific Products 550...
Page 565: ......