Section 8. Operation
357
and arguments and the commands wherein they are used. Parameters and
arguments for specific commands are listed in the following sections.
Table 87.
API Commands, Parameters, and Arguments
Parameter
Commands in which the
parameter is used
Function of parameter
Argument(s)
uri
•
BrowseSymbols
•
DataQuery
•
ClockSet
•
ClockCheck
•
ListFiles
Specifies the data source.
•
source: dl
(datalogger is data
source): default,
applies to all
commands listed in
column 2.
•
tablename.fieldname
:
applies only to
BrowseSymbols
,
and
DataQuery
format
•
BrowseSymbols
•
DataQuery
•
ClockSet
•
ClockCheck
•
FileControl
•
ListFiles
Specifies response format.
•
html
,
xml
,
json
:
apply to all
commands listed in
column 2.
•
toa5
and
tob1
apply
only to
DataQuery
mode
DataQuery
Specifies range of data with
which to respond.
•
most-recent
•
since-time
•
since-record
•
data-range
•
backfill
p1
DataQuery
•
maximum number of
records (when using
most-recent
argument).
•
beginning date and/or
time (when using
since-time
,or
date-
range
arguments).
•
beginning record
number (when using
since-record
argument).
•
interval in seconds
(when using
backfill
argument).
•
integer number of
records (when using
most-recent
argument)
•
time in defined
format (when using
since-time
,or
date-
range
arguments, see
Time Syntax
(p. 358)
section)
•
integer record
number(when using
since-record
argument).
•
integer number of
seconds (when using
backfill
argument).
Summary of Contents for CR850
Page 2: ......
Page 4: ......
Page 6: ......
Page 26: ...Table of Contents 26...
Page 30: ...Section 2 Cautionary Statements 30...
Page 32: ...Section 3 Initial Inspection 32...
Page 35: ...Section 4 Quickstart Tutorial 35 Figure 2 Wiring panel...
Page 55: ...Section 4 Quickstart Tutorial 55 Figure 24 PC200W View data utility...
Page 78: ...Section 5 System Overview 78...
Page 80: ...Section 6 CR800 Specifications 80...
Page 267: ...Section 7 Installation 267 Figure 84 Running average signal attenuation...
Page 268: ...Section 7 Installation 268...
Page 384: ...Section 8 Operation 384 Figure 113 Using the keyboard display...
Page 387: ...Section 8 Operation 387 Figure 116 Real time custom...
Page 388: ...Section 8 Operation 388 8 8 1 3 Final Storage Tables Figure 117 Final storage tables...
Page 389: ...Section 8 Operation 389 8 8 2 Run Stop Program Figure 118 Run Stop Program...
Page 390: ...Section 8 Operation 390 8 8 3 File Display Figure 119 File display...
Page 396: ...Section 8 Operation 396...
Page 402: ...Section 9 Maintenance 402...
Page 450: ...Section 11 Glossary 450...
Page 504: ...Appendix A CRBasic Programming Instructions 504...
Page 526: ...Appendix B Status Table and Settings 526...
Page 530: ...Appendix C Serial Port Pinouts 530...
Page 536: ...Appendix E FP2 Data Format 536...
Page 550: ...Appendix F Other Campbell Scientific Products 550...
Page 565: ......