Section 7. Installation
182
CRBasic
Example
33.
Using
Alternate
Concurrent
Command
(aC)
'Code to use when back to back SDI-12 concurrent measurement commands not desired
'Main Program
BeginProg
'Preset first measurement command to C!
For
X = 1
To
4
cmd(X) = "C!"
Next
X
'Set 5 s scan rate
Scan
(5,Sec,0,0)
'Other measurements here
'Set 5 minute measurement rate
If
TimeIntoInterval
(0,5,Min)
Then
RunSDI12 = True
'Begin measurement sequence
If
RunSDI12 = True
Then
For
X = 1
To
4
Temp_Tmp(X) = 2e9
'when 2e9 changes, indicates a change
Next
X
'Measure SDI-12 sensors
SDI12Recorder
(Temp_Tmp(1),1,0,cmd(1),1.0,0)
SDI12Recorder
(Temp_Tmp(2),1,1,cmd(2),1.0,0)
SDI12Recorder
(Temp_Tmp(3),1,2,cmd(3),1.0,0)
SDI12Recorder
(Temp_Tmp(4),1,3,cmd(4),1.0,0)
'Control Measurement Event
For
X = 1
To
4
If
cmd(X) = "C!"
Then
Retry(X) = Retry(X) + 1
If
Retry(X) > 2
Then
IndDone(X) = -1
'Test to see if ttt expired. If ttt not expired, load "1e9" into first
'variable then moves to next instruction. If ttt expired, issue
'aDv! command(s).
If
((Temp_Tmp(X) = 2e9)
OR
(Temp_Tmp(X) = 1e9))
Then
cmd(X) = "C"
'Start sending "C" command.
ElseIf
(Temp_Tmp(X) = NAN) Then
'Comms failed or sensor not attached
cmd(X) = "C!"
'Start measurement over
Summary of Contents for CR850
Page 2: ......
Page 4: ......
Page 6: ......
Page 26: ...Table of Contents 26...
Page 30: ...Section 2 Cautionary Statements 30...
Page 32: ...Section 3 Initial Inspection 32...
Page 35: ...Section 4 Quickstart Tutorial 35 Figure 2 Wiring panel...
Page 55: ...Section 4 Quickstart Tutorial 55 Figure 24 PC200W View data utility...
Page 78: ...Section 5 System Overview 78...
Page 80: ...Section 6 CR800 Specifications 80...
Page 267: ...Section 7 Installation 267 Figure 84 Running average signal attenuation...
Page 268: ...Section 7 Installation 268...
Page 384: ...Section 8 Operation 384 Figure 113 Using the keyboard display...
Page 387: ...Section 8 Operation 387 Figure 116 Real time custom...
Page 388: ...Section 8 Operation 388 8 8 1 3 Final Storage Tables Figure 117 Final storage tables...
Page 389: ...Section 8 Operation 389 8 8 2 Run Stop Program Figure 118 Run Stop Program...
Page 390: ...Section 8 Operation 390 8 8 3 File Display Figure 119 File display...
Page 396: ...Section 8 Operation 396...
Page 402: ...Section 9 Maintenance 402...
Page 450: ...Section 11 Glossary 450...
Page 504: ...Appendix A CRBasic Programming Instructions 504...
Page 526: ...Appendix B Status Table and Settings 526...
Page 530: ...Appendix C Serial Port Pinouts 530...
Page 536: ...Appendix E FP2 Data Format 536...
Page 550: ...Appendix F Other Campbell Scientific Products 550...
Page 565: ......