Section 8. Operation
317
Table 71.
CR800 SRAM Memory
Use
Comments
Static Memory
Operational memory used by the operating system regardless of the user
program. This sector is rebuilt at power-up, program re-compile, and watchdog
events.
----------------------------------
Operating Settings and Properties
"Keep"
memory. Stores settings such as PakBus address, station name, beacon
intervals, neighbor lists, etc. Also stores dynamic properties such as the routing
table, communications timeouts, etc.
----------------------------------
CRBasic Program
Operating Memory
Stores the currently compiled and running user program. This sector is rebuilt on
power-up, recompile, and watchdog events.
----------------------------------
Variables & Constants
Stores variables in the user program. These values may persist through power-
up, recompile, and watchdog events if the
PreserveVariables
instruction is in
the running program.
----------------------------------
Final-Storage Data Tables
Final Storage is given lowest
priority in SRAM memory
allocation.
Stores data resulting from CR800 measurements. This memory is termed "Final
Storage." Fills memory remaining after all other demands are satisfied.
Configurable as ring or fill-and-stop memory. Compile error occurs if
insufficient memory is available for user-allocated data tables.
----------------------------------
Communications Memory 1
Construction and temporary storage of PakBus® packets.
----------------------------------
Communications Memory 2
Constructed Routing Table: list of known nodes and routes to nodes. Routers use
more space than leaf nodes because routes to neighbors must be remembered.
Increasing the PakBusNodes field in the
Status
table will increase this allocation.
----------------------------------
USR: drive
<= 3.6 MB (4 MB Mem)
<= 1.5 MB (2 MB Mem)
Less on older units with more
limited memory.
Optionally allocated. Holds image files. Holds a copy of Final Storage when
TableFile()
instruction used. Provides memory for
FileRead()
and
FileWrite()
operations. Managed in File Control. Status reported in
Status
table fields
"USRDriveSize" and "USRDriveFree."
Summary of Contents for CR850
Page 2: ......
Page 4: ......
Page 6: ......
Page 26: ...Table of Contents 26...
Page 30: ...Section 2 Cautionary Statements 30...
Page 32: ...Section 3 Initial Inspection 32...
Page 35: ...Section 4 Quickstart Tutorial 35 Figure 2 Wiring panel...
Page 55: ...Section 4 Quickstart Tutorial 55 Figure 24 PC200W View data utility...
Page 78: ...Section 5 System Overview 78...
Page 80: ...Section 6 CR800 Specifications 80...
Page 267: ...Section 7 Installation 267 Figure 84 Running average signal attenuation...
Page 268: ...Section 7 Installation 268...
Page 384: ...Section 8 Operation 384 Figure 113 Using the keyboard display...
Page 387: ...Section 8 Operation 387 Figure 116 Real time custom...
Page 388: ...Section 8 Operation 388 8 8 1 3 Final Storage Tables Figure 117 Final storage tables...
Page 389: ...Section 8 Operation 389 8 8 2 Run Stop Program Figure 118 Run Stop Program...
Page 390: ...Section 8 Operation 390 8 8 3 File Display Figure 119 File display...
Page 396: ...Section 8 Operation 396...
Page 402: ...Section 9 Maintenance 402...
Page 450: ...Section 11 Glossary 450...
Page 504: ...Appendix A CRBasic Programming Instructions 504...
Page 526: ...Appendix B Status Table and Settings 526...
Page 530: ...Appendix C Serial Port Pinouts 530...
Page 536: ...Appendix E FP2 Data Format 536...
Page 550: ...Appendix F Other Campbell Scientific Products 550...
Page 565: ......