Section 7. Installation
242
'Data Tables
'Table output on two intervals depending on condition.
'note the parenthesis around the TriggerVariable AND statements
'Status table datafilldays field is low
DataTable
(TwoInt,(int_fast
AND
TimeIntoInterval
(0,5,Sec))
OR
(int_slow
AND
_
TimeIntoInterval
(0,15,sec)),-1)
Minimum
(1,batt_volt,FP2,0,False)
Sample
(1,PTemp,FP2)
Maximum
(1,counter(1),Long,False,False)
Minimum
(1,counter(1),Long,False,False)
Maximum
(1,deltaT,FP2,False,False)
Minimum
(1,deltaT,FP2,False,False)
Average
(1,deltaT,IEEE4,false)
EndTable
'Main Program
BeginProg
Scan
(1,Sec,0,0)
PanelTemp
(PTemp,250)
Battery
(Batt_volt)
counter(1) = counter(1) + 1
'thermocouple measurement
TCDiff
(AirTempC,1,mV2_5C,1,TypeT,PTemp,True ,0,250,1.0,0)
'calculate the difference in air temperature and panel temperature
deltaT = airtempC - PTemp
'when the difference in air temperatures is >=3 turn LED on
'and trigger the data table's faster interval
If
deltaT >= 3
Then
PortSet
(4,true)
int_fast = true
int_slow = false
Else
PortSet
(4,false)
int_fast = false
int_slow = true
EndIf
'Call Output Tables
CallTable
TwoInt
NextScan
EndProg
7.8.15 PulseCountReset Instruction
PulseCountReset
is used in rare instances to force the reset or zeroing of CR800
pulse accumulators (see
Measurement Inputs
(p. 60)
).
PulseCountReset
is needed in applications wherein two separate
PulseCount()
instructions in separate scans use the same pulse-input channel. While the
compiler does not allow multiple
PulseCount()
instructions in the same scan to
use the same channel, multiple scans using the same channel are allowed.
PulseCount()
information is not maintained globally, but for each individual
instruction occurrence. So, if a program needs to alternate between fast and slow
Summary of Contents for CR850
Page 2: ......
Page 4: ......
Page 6: ......
Page 26: ...Table of Contents 26...
Page 30: ...Section 2 Cautionary Statements 30...
Page 32: ...Section 3 Initial Inspection 32...
Page 35: ...Section 4 Quickstart Tutorial 35 Figure 2 Wiring panel...
Page 55: ...Section 4 Quickstart Tutorial 55 Figure 24 PC200W View data utility...
Page 78: ...Section 5 System Overview 78...
Page 80: ...Section 6 CR800 Specifications 80...
Page 267: ...Section 7 Installation 267 Figure 84 Running average signal attenuation...
Page 268: ...Section 7 Installation 268...
Page 384: ...Section 8 Operation 384 Figure 113 Using the keyboard display...
Page 387: ...Section 8 Operation 387 Figure 116 Real time custom...
Page 388: ...Section 8 Operation 388 8 8 1 3 Final Storage Tables Figure 117 Final storage tables...
Page 389: ...Section 8 Operation 389 8 8 2 Run Stop Program Figure 118 Run Stop Program...
Page 390: ...Section 8 Operation 390 8 8 3 File Display Figure 119 File display...
Page 396: ...Section 8 Operation 396...
Page 402: ...Section 9 Maintenance 402...
Page 450: ...Section 11 Glossary 450...
Page 504: ...Appendix A CRBasic Programming Instructions 504...
Page 526: ...Appendix B Status Table and Settings 526...
Page 530: ...Appendix C Serial Port Pinouts 530...
Page 536: ...Appendix E FP2 Data Format 536...
Page 550: ...Appendix F Other Campbell Scientific Products 550...
Page 565: ......