![Campbell CR850 Operator'S Manual Download Page 366](http://html1.mh-extra.com/html/campbell/cr850/cr850_operators-manual_3829356366.webp)
Section 8. Operation
366
JSON Response
When
json
is entered in the
DataQuery
format
parameter, the response will be
formatted as CSIJSON. Following is an example response:
{
.."head": {
...."transaction": 0,
...."signature": 26426,
...."environment": {
......"station_name": "Q2",
......"table_name": "BallastLine",
......"model": "CR1000",
......"serial_no": "18583",
......"os_version": "CR1000.Std.25",
......"prog_name": "CPU:IndianaHarbor_081712.CR1"
....},
...."fields": [{
......"name": "Induced_Water",
......"type": "xsd:float",
......"process": "Smp",
......"settable": false}]
},
......"data": [{
......"time": "2012-08-21T22:41:50",
......"no": 104,
......"vals": [66]
},{
......"time": "2012-08-21T22:42:00",
......"no": 105,
......"vals": [66]
},{
......"time": "2012-08-21T22:42:10",
......"no": 106,
......"vals": [66]
},{
......"time": "2012-08-21T22:42:20",
......"no": 107,
......"vals": [66]
},{
......"time": "2012-08-21T22:42:30",
......"no": 108,
......"vals": [66]
}]}
TOA5 Response
When
toa5
is entered in the
DataQuery
format
parameter, the response will be
formated as Campbell Scientific TOA5. Following is an example response:
"TOA5","TXSoil","CR1000","No_SN","CR1000.Std.25","TexasRun_1b.CR
2","12645","_1Hr"
"TIMESTAMP","RECORD","ID","_6_inch","One","Two","Three","Temp_F_
Avg","Rain_in_Tot"
"TS","RN","","","","","","",""
"","","Smp","Smp","Smp","Smp","Smp","Avg","Tot"
"2012-05-03 17:00:00",0,0,-0.8949984,-0.95232,-0.8949984,-
0.8637322,2.144136,0.09999999
"2012-05-03 18:00:00",1,0,-0.9106316,-0.9731642,-0.9210536,-
0.8845763,72.56885,0
Summary of Contents for CR850
Page 2: ......
Page 4: ......
Page 6: ......
Page 26: ...Table of Contents 26...
Page 30: ...Section 2 Cautionary Statements 30...
Page 32: ...Section 3 Initial Inspection 32...
Page 35: ...Section 4 Quickstart Tutorial 35 Figure 2 Wiring panel...
Page 55: ...Section 4 Quickstart Tutorial 55 Figure 24 PC200W View data utility...
Page 78: ...Section 5 System Overview 78...
Page 80: ...Section 6 CR800 Specifications 80...
Page 267: ...Section 7 Installation 267 Figure 84 Running average signal attenuation...
Page 268: ...Section 7 Installation 268...
Page 384: ...Section 8 Operation 384 Figure 113 Using the keyboard display...
Page 387: ...Section 8 Operation 387 Figure 116 Real time custom...
Page 388: ...Section 8 Operation 388 8 8 1 3 Final Storage Tables Figure 117 Final storage tables...
Page 389: ...Section 8 Operation 389 8 8 2 Run Stop Program Figure 118 Run Stop Program...
Page 390: ...Section 8 Operation 390 8 8 3 File Display Figure 119 File display...
Page 396: ...Section 8 Operation 396...
Page 402: ...Section 9 Maintenance 402...
Page 450: ...Section 11 Glossary 450...
Page 504: ...Appendix A CRBasic Programming Instructions 504...
Page 526: ...Appendix B Status Table and Settings 526...
Page 530: ...Appendix C Serial Port Pinouts 530...
Page 536: ...Appendix E FP2 Data Format 536...
Page 550: ...Appendix F Other Campbell Scientific Products 550...
Page 565: ......