Section 7. Installation
129
Data Types in Final-Storage Memory
Name Argument
Description
Word
Size
(Bytes)
Notes
Resolution / Range
Long
Long
Signed integer
4
Use to store count data in the
range of
±
2,147,483,648
Speed: integer math is faster than
floating point math.
Resolution: 32 bits. Compare to 24
bits in IEEE4.
Suitable for storing whole
numbers, counting number, and
integers in final-storage memory.
If storing non-integers, the
fractional portion of the value is
lost.
–2,147,483,648 to +2,147,483,647
UINT2
UINT2
Unsigned
integer
2
Use to store positive count data ≤
+65535.
Use to store port or flag status. See
CRBasic example
Load binary
information into a variable
(p. 139).
When
Public
FLOAT
s convert to
UINT2
at final data storage, values
outside the range 0 – 65535 yield
unusable data.
INF
converts to
65535
.
NAN
converts to 0.
0 to 65535
UINT4
UINT4
Unsigned
integer
4
Use to store positive count data ≤
2147483647.
Other uses include storage of long
ID numbers (such as are read from
a bar reader), serial numbers, or
address.
May also be required for use in
some Modbus devices.
0 to 4,294,967,295 (2
32
)
Boolean
Boolean
Signed integer
4
Use to store true or false states,
such as states of flags and control
ports. 0 is always false. –1 is
always true. Depending on the
application, any other number may
be interpreted as true or false. See
the section
True = -1, False = 0
(p.
To save memory, consider
using
UINT2
or
BOOL8
.
True =
–
1 or any number ≥ 1
False = any number ≥ 0 and < 1
Bool8
Bool8
Integer
1
8 bits (0 or 1) of information. Uses
less space than 32-bit BOOLEAN.
Holding the same information in
BOOLEAN will require 256 bits.
See
Bool8 Data Type
(p. 193).
True = 1, False
= 0
Summary of Contents for CR800 Series
Page 2: ......
Page 4: ......
Page 6: ......
Page 32: ......
Page 34: ......
Page 54: ......
Page 92: ......
Page 310: ......
Page 446: ...Section 8 Operation 446 8 11 2 Data Display FIGURE 100 CR1000KD Displaying Data ...
Page 448: ...Section 8 Operation 448 FIGURE 102 CR1000KD Real Time Custom ...
Page 449: ...Section 8 Operation 449 8 11 2 3 Final Storage Data FIGURE 103 CR1000KD Final Storage Data ...
Page 450: ...Section 8 Operation 450 8 11 3 Run Stop Program FIGURE 104 CR1000KD Run Stop Program ...
Page 452: ...Section 8 Operation 452 FIGURE 106 CR1000KD File Edit ...
Page 456: ......
Page 462: ......
Page 523: ...Section 11 Glossary 523 FIGURE 116 Relationships of Accuracy Precision and Resolution ...
Page 524: ......
Page 526: ......
Page 556: ......
Page 558: ......
Page 560: ......
Page 597: ......