background image

 

 

 

 

 

 

 

 

 

WA0123E_WSD00T/WSD00T_LD_User Manual_R10 

 

CAPETTI ELETTRONICA s.r.l.  -   Strada Stratta 57 
10090 CASTIGLIONE TORINESE  -  TORINO  -  ITALY 
VAT 04837130014 - Phone 011.981.98.11 -  Fax 011.981.98.210 
e-mail [email protected]  -  web www.capetti.it

 

 

 

1/8

 

 

WSD00T / WSD00T_LD 

User Manual 

1.

 

Description. 

 The 

WSD00T

  and  the 

WSD00T_LD

  are 

dataloggers

  with  one  input  channels  to  acquire  indoor  temperature,  with  storage 

functionality of samples acquired. 

 

 

2.

 

Device preset and use mode. 

a.

 

Wireless Mode: 

No setup operation is needed. Typically the system is configured from factory so the device is already associated to the system 

basestation

.  The  device  is  in 

STANDBY

  mode  for  which  is  necessary  to  start  it  with  the 

TEST

  command  (

refer  to  chapter

  5

  -  

Installation procedure

.

). 

Otherwise, in case the device is in 

FACTORY RESET

 mode, that means it's ready for connecting to an existing system, in order to 

associate  it,  make  reference  to  the  “

WineCap  System  -  User  Manual  R28  -  chapter  4.3.1  Probe/datalogger  association  procedure.

” 

software  manual.  Is  necessary  to  use  the  "

WineCapManager

"  software  on  the  PC  connected  to  the 

basestation

  that  will  be 

coupled with the device. 

b.

 

USB Logger Mode: 

For  this  operation  mode,  stand-alone  with  data  downloads  through  USB,  the  connection  with  the  PC  and  the 

WineCapManager

” running on it is necessary in order to modify the device 's operation mode. The sampling interval must be 

set with the device in "

STAND-ALONE

" mode and automatically, the  device 's clock is aligned with the PC's clock, in order to 

assure the temporal reference of the sample. 

Sampling operations start may be selected disconnecting the USB cable or giving the proper command with the magnetic key. 
(

refer  chapter 

6

  - 

Stand-alone  USB  datalogger  installation

.

).  More  details  on  device  's  connection/disconnection  through  the  USB 

cable are available on the 

WineCap System - User Manual R28

 

manual. 

c.

 

On field transition from USB to Wireless datalogger: 

This transition is practicable in field, during the sampling period, using the wireless network association command. When the 
association  is  done,  the 

datalogger

  becomes  a  wireless 

datalogger

  and,  besides  sending  new  measures  to  the 

basestation

starts a download process towards the same 

basestation

 of the measures acquired during the stand alone period. 

 

 

 

 

 

 

 

 

Picture 1 - Product Image

 

Summary of Contents for WSD00T

Page 1: ...r software on the PC connected to the basestation that will be coupled with the device b USB Logger Mode For this operation mode stand alone with data downloads through USB the connection with the PC and the WineCapManager running on it is necessary in order to modify the device s operation mode The sampling interval must be set with the device in STAND ALONE mode and automatically the device s cl...

Page 2: ... WSD00T_LD User Manual 3 Wireless device user interface The user interface consists of a virtual button that can be activated using the WineCapKey and of a two coloured led To give a command user must approach the WineCapKey to the device s sensible area and keep it in that position the following picture Pic 3 shows device s sensible points Picture 2 Device positioning Picture 3 WineCapKey positio...

Page 3: ... table Radio signal quality 5 flashes 5 flashes FACTORY RESET The device performs the memory deleting procedure and goes in STOP status All samples configuration and wireless network data associated are LOST To reactivate the device a new association and configuration procedure is necessary ENROLL command Also in this case the FACTORY RESET command must be given twice to confirm it At the command ...

Page 4: ... amber flashes Sufficient 1 red flash Insufficient 1 red flash 2 long OUT OF RANGE Network searching 2 red flashes 2 long STANDBY Short long short red flashes series FACTORY RESET Device not enrolled Optimize reception selecting the best position small movements can help If the signal is absent or insufficient at the install point a WR12 router should be put between refer to WineCapManager User Ma...

Page 5: ...le Flash count Stand alone mode STATUS 1 green flash 2 seconds long ACTIVE 2 red flashes 2 seconds long STANDBY Sequence of red flashes short 2 seconds long short FACTORY RESET INVALID datalogger clock PC connection required 7 Shutting off Reactivating the device If the device is shut off and left unused for a long time you can issue the STANDBY command Its corresponds to the command number 4 and ...

Page 6: ... to 24 hours 10 minutes default Datalogger capacity 128 000 samples for each channel Working temperature Operative 30 C 60 C Warehousing 40 C 70 C Radio frequency ISM 868MHz Radio coverage Up to 6Km in line of sight can be extended using WR12 battery powered routers Sealing IP30 Dimensions WSD00T 80 x 80 x 25mm WSD00T_LD 120 x 80 x 33 5mm Weight WSD00T 100g WSD00T_LD 224g Case material ABS Mountin...

Page 7: ...RONICA s r l Strada Stratta 57 10090 CASTIGLIONE TORINESE TORINO ITALY VAT 04837130014 Phone 011 981 98 11 Fax 011 981 98 210 e mail info capetti it web www capetti it 7 8 WSD00T WSD00T_LD User Manual 9 Mechanical dimensions Picture 7 Mechanical dimensions ...

Page 8: ...irective 2011 65 CE that restricts the use of substances in the manufacturing of electronic devices The WEEE logo on the label indicates that this product is compliant with the WEEE EC Directive This symbol valid only in the European Union countries indicates that the product it is applied to MUST NOT be discarded with ordinary household or industrial waste but must be sent to an authorized recept...

Reviews: