Chapter 6: Configuration and alignment
Installation menu
Page 6-23
Configuring port allocations in PTP wireless topology
The Interface Configuration page controls the allocation of the Main PSU Port, Aux Port and
SFP Port to the Data Service, Second Data Service, Management Service and Local
Management Service.
PTP 670 supports exactly one instance of the Data Service, and this service is always mapped
to one of the three wired ports. It is not possible to operate a link without any port selected to
the Data Service.
PTP 670 supports zero or one instances of the optional Second Data Service. The Second Data
Service can be disabled or mapped to any available port, except for the port already allocated
to the Data Service.
PTP 670 supports zero or one instances of the optional Management Service. The Management
Service can be used to access the management agent at the local unit. If the wireless link is
established, the Management Service can also be used to access the management agent at the
remote unit and other devices connected in the remote management network. The
Management Service can be mapped to a port that is already used for the Data Service or
Second Data Service to provide In-Band Management. Alternatively, the Management Service
can be allocated to a dedicated port to provide Out-of-Band Management.
PTP 670 also supports an optional Local Management Service, providing a connection from a
wired port to the local management agent. Any port not already selected is available for
selection to the Local Management Service. The Local Management Service does not connect
across the wireless link.
The PTP 670 must always be manageable through one of three ports. Therefore it is not
possible to disable the Management Service unless at least one port is allocated to the Local
Management Service.
For more details, see
Ethernet port allocation for PTP topology
Configuring port allocations in HCMP wireless topology
The Interface Configuration page controls the allocation of the Main PSU Port, Aux Port and
SFP Port to the Data Service, Management Service and Local Management Service.
PTP 670 supports exactly one instance of the Data Service, and this service is always mapped
to one or more of the three wired ports. It is not possible to operate a link without any port
selected to the Data Service.
PTP 670 supports zero or one instances of the optional Management Service. The Management
Service can be used to access the management agent at the local unit. If the wireless link is
established, the Management Service can also be used to access the management agent at the
remote unit and other devices connected in the remote management network. The
Management Service can be mapped to the set of ports that are already used for the Data
Service to provide In-Band Management. Alternatively, the Management Service can be
allocated to one or more dedicated ports to provide Out-of-Band Management.
PTP 670 also supports an optional Local Management Service, providing a connection from a
wired port to the local management agent. Any port not already selected is available for
selection to the Local Management Service. The Local Management Service does not connect
across the wireless link.