Chapter 5: Installation
Installing a NIDU
Page 5-43
Using the DC power connector
Use this procedure to connect the NIDU to the AC+DC Enhanced Power Injector 56V (Cambium
part number C000065L002C) or to an independent DC supply with an optional backup DC
supply:
1 Strip the two wires of the main DC supply cable and screw them into the first and second terminals
of the DC power connector (Cambium part number C000065L044). The first terminal is negative
(black wire) and the second is positive (red wire). If a backup supply is required, use the third and
fourth terminals of the connector:
2 Plug the DC power connector into the NIDU DC interface: