![Cambium PTP 670 Series User Manual Download Page 116](http://html.mh-extra.com/html/cambium/ptp-670-series/ptp-670-series_user-manual_485665116.webp)
Chapter 2: System hardware
Ethernet cabling
Page 2-31
Table 32 Aux and copper SFP Ethernet standards and cable length restrictions
ODU drop cable
Power over Ethernet
Ethernet supported
(*1)
Maximum cable
length (*2)
Aux – auxiliary device
POE to auxiliary
device
100BASE-TX
1000BASE-T
100 m (330 ft)
None
100BASE-TX
100 m (330 ft)
SFP (copper) – linked device
None
100BASE-TX
100 m (330 ft)
(*1) 10BASE-T is not supported by PTP 670.
(*2) Maximum length of Ethernet cable from the ODU to the linked device.
Outdoor copper Cat5e Ethernet cable
For copper Cat5e Ethernet connections from the ODU to the PSU, LPUs and other devices, use
Cat5e cable that is gel-filled and shielded with copper-plated steel, for example Superior Essex
type BBDGe. This is known as “drop cable” (
Caution
Always use Cat5e cable that is gel-filled and shielded with copper-plated steel.
Alternative types of drop cable are not supported by Cambium Networks for the PTP
670.
Order Superior Essex type BBDGe cable from Cambium Networks (
). Other lengths of
this cable are available from Superior Essex.
Figure 21 Outdoor drop cable