Chapter 5: Installation
Installing the copper Cat5e Ethernet interface
Page 5-18
Pin
Color
(Supplied cable)
Color
(Conventional)
Pins on plug face
1
Light Orange
White/Orange
2
Orange
Orange
3
Light Green
White/Green
4
Blue
Blue
5
Light Blue
White/Blue
6
Green
Green
7
Light Brown
White/Brown
8
Brown
Brown
Hoist and fix the main drop cable
Warning
Failure to obey the following precautions may result in injury or death:
•
Use the hoisting grip to hoist one cable only. Attempting to hoist more than one
cable may cause the hoisting grip to break or the cables to fall.
•
Do not use the hoisting grip for lowering cable unless the clamp is securely in place.
•
Maintain tension on the hoisting grip during hoisting. Loss of tension can cause
dangerous movement of the cable and result in injury or death to personnel.
•
Do not release tension on the grip until after the grip handle has been fastened to the
supporting structure.
•
Do not apply any strain to the RJ45 connectors.
Caution
Do not lay the drop cable alongside a lightning air terminal.
1 Hoist the top end of the main drop cable up to the top LPU, following the hoist manufacturer’s
instructions. When the cable is in position, fasten the grip handle to the supporting structure
and remove the hoist line.
2 Connect the main drop cable to the top LPU by following the procedure
3 Run the main drop cable to the site of the bottom LPU.
4 Attach the main drop cable to the supporting structure using site approved methods.