Equipm ent specificat ions
Chapt er 4: Reference inform at ion
4- 16
phn- 2513_004v000 ( Oct 2012)
Coupler losses and isolation
contains ODU port return losses and isolation figures for Cambium-supplied ODU
couplers. These figures apply to both symmetric and asymmetric couplers.
Ta ble 9 2
ODU coupler ret urn losses and isolat ion
Ba n ds
OD U p or t r e t u r n loss
I sola t ion be t w e e n OD U p or t s
6 GHz
18 dB minimum
20 dB minimum
7 GHz to 38 GHz
20 dB maximum
20 dB minimum
contains ODU port insertion losses for Cambium-supplied ODU couplers.
Ta ble 9 3
ODU coupler insert ion losses
Ba n ds
Cou p le r t yp e
OD U p or t m a x im u m in se r t ion losse s
6 GHz
3 dB symmetric
6 dB asymmetric
Main 1.9 dB, Standby 6.5 dB
7 GHz to 26 GHz
3 dB symmetric
3.8 dB
6 dB asymmetric
Main 1.8 dB, Standby 7.2 dB
32 GHz to 38 GHz
3 dB symmetric
4.0 dB
6 dB asymmetric
Main 2.0 dB, Standby 7.4 dB