I nst alling ant ennas and ODUs
Chapt er 5: I nst allat ion
5- 16
phn- 2513_004v000 ( Oct 2012)
5
Fit the remote mount to the tower. Fit an ‘O’ ring seal to the antenna interface
and secure the plain flange of flexible waveguide to the antenna. Ensure that the
waveguide cavity orientation matches the opening in the antenna. Secure the
flexible waveguide using four of the shorter screws to the antenna. Fit each
screw with a spring washer and a plain washer.
6
Fit the rubber inserts from the hanger kit to the flex waveguide.
7
Insert the rubber insert and flex waveguide into the hanger.