PTP 800 Series User Guide
Task 7: Configuring wireless int erface
phn- 2513_004v000 ( Oct 2012)
6- 67
At t r ibu t e
M e a n in g
Site Name
The Site Name where the unit is to be installed.
For 1+1 Hot Standby links, it is recommended that the
Primary and Secondary CMUs installed at the same end
are configured with the same Site Name. An individual
unit within a network is then identifiable from the three
attributes: Link Name, Site Name and Primary Secondary
Mode.
RFU
RFU Status
The status of the RFU. If the RFU is not connected to the
CMU, this attribute indicates “No Response” with a red
background.
RFU Installation
Platform
The type of RFU installed.
If an RFU is already connected, the CMU detects and
identifies the type, and this attribute cannot be changed.
If no RFU is connected, this attribute can be pre-set to show
the RFU platform that will be installed (IRFU-HP, ODU-A or
ODU-B).
RFU Branching
Configuration
Only displayed when RFU Installation Platform is set to ‘IRFU-
HP’.
The required IRFU branching configuration:
RFU 1+0
RFU 1+0 MHSB Ready (Equal)
RFU 1+0 MHSB Ready (Unequal)
RFU 1+1 MHSB (Equal)
RFU 1+1 MHSB (Unequal)
RFU 1+1 Tx MHSB / Rx SD
RFU 2+0
RFU Transceiver
Location
Only displayed when RFU Installation Platform is set to ‘IRFU-
HP’ and RFU Branching Configuration is not ‘RFU 1+0’.
The CMU must know the location of the transceiver within the
IRFU to which it is connected:
Left (TRx A)
Right (TRx B)
Summary of Contents for PTP 800 Series
Page 1: ...Cambium PTP 800 Series User Guide System Release 800 05 02 ...
Page 40: ...Licensing requirements About This User Guide 10 phn 2513_004v000 Oct 2012 ...
Page 232: ...Limit of liability Chapter 3 Legal information 3 22 phn 2513_004v000 Oct 2012 ...
Page 322: ...Radiation hazard assessm ent Chapter 4 Reference information 4 90 phn 2513_004v000 Oct 2012 ...
Page 428: ...Replacing IRFU components Chapter 5 Installation 5 106 phn 2513_004v000 Oct 2012 ...
Page 630: ...Using recovery mode Chapter 7 Operation 7 78 phn 2513_004v000 Oct 2012 ...