INSTRUCTIONAL MANUAL
2750L-P/4500L-P/6000L-P
August, 2001
Rev. K
-68-
3.8.1 CIIL
ELEMENTS
The Control Interface Intermediate Language (CIIL) elements are:
OP-CODES:
FNC,
SET,
SRX,
SRN,
CLS, OPN, RST, CNF, IST, INX, FTH, STA,
GAL
NOUN:
ACS
NOUN MODIFIERS:
VOLT, FREQ, PANG, CURL, SYNI, POWR, APOW, CURR, TRSC
CHANNEL DESIGNATORS
:CH00, :CH01, :CH02, :CH03
The only noun recognized by the power source is ACS for AC Signal. The only non-operational code (no-op)
in a string is an ASCII space. Numeric expressions may be represented by explicit decimal values (e.g., 115.0)
or exponential values (e.g., 0.115E3). The exponent field may be either a one-digit or two-digit form (e.g., E1
or E01) signed or unsigned with a range from E-24 to E+24.
Summary of Contents for 12000L-1P
Page 119: ...INSTRUCTIONAL MANUAL 2750L P 4500L P 6000L P August 2001 Rev K 115 Figure 6 1 MODULE LOCATION...
Page 138: ...INSTRUCTIONAL MANUAL 2750L P 4500L P 6000L P August 2001 Rev K 134 Figure 14 EMERGENCY VOLTAGE...
Page 148: ...INSTRUCTIONAL MANUAL 2750L P 4500L P 6000L P August 2001 Rev K 144 FIGURE 2...