Full power is available at the maximum output voltage on either of two voltage ranges. The standard voltage
ranges are 135 and 270. Three optional voltage range pairs are available: 67.5/135, 156/312 and 200/400.
All "P" Power systems except for the 6000L will deliver full power from 45 to 2000 Hz. All 6000L-P power systems will
deliver full power from 45 to 440 Hz.
The 2750L-3P, 4500L-3P and 6000L-3P will deliver full power from 45 to 5000 Hz. The power sources are illustrated in
Figure 1-1. The 200/400 volt range (EHV Option) is specified for full power from 45 to 1000 Hz.
The output frequency of all "P" power systems can be programmed down to 17 Hz at a reduced output voltage.
1.3
ACCESSORY EQUIPMENT/RACK SLIDES
General Devices Model CTS-1-20-B307-2 rack slides may be attached to the sides of the power source using 10-32 X
1/2 flat head screws.
1.4 SPECIFICATIONS
Table 1-1 contains the operation specifications of the AC Power System. All specifications are tested in accordance
with standard California Instruments test procedures. The following specifications apply for operation at 100% of full
scale voltage, constant line voltages and under no-load and with External Sense Lines connected unless specified
otherwise.