-73-
the subassemblies most likely to be at fault.
The IST (internal self test) OP-code produces the same response described for CNF.
3.8.3.7 INX
The INX (initialize) OP-code is a request for data from the power source. A request for the time required to measure
the voltage of all phases consists of the following strings:
FNC ACS VOLT :CHnn <CR> <LF>
INX VOLT <CR> <LF>
The power source then responds with:
<SP> 5 <CR> <LF>
The power source response indicates that 5 seconds will be required to perform the measurement. The measurement
time values are stored in read-only memory in the power source.
Note that the INX OP-code must be preceded by an FNC OP-code string containing the noun modifier for which INX
will request data.