Fig. 7.19 – System Upgrade pop-up Window
In order to upgrade the system firmware, follow these steps:
6. Select the
Upgrade Running Image
command by means of the TAB key and
then press ENTER: as this command is entered, the system will be automatically
reset and the currently running image file will be substituted by the stored image
file displayed in the window;
To erase the file from the flash memory select the
Delete the stored image
command
and press ENTER.
To exit the System Upgrade window select the
Exit
command and press ENTER.
7.1.22
The SETUP Menu: Reset Flag
This command opens the
Reset Flag
pop-up window (
Fig. 7.20
) which allows to enable
the different reset conditions and to assert TRUE the RESET FLAG output signal (and
relevant LED alight) accordingly.
Specifically, the RESET FLAG output signal can be asserted TRUE at the occurrence of
one of the following types of resets:
•
PC Failure Self Reset
, i.e. a reset of the CPU section due to a failure;
•
PC User Software Reset,
i.e. an auto-reset of the CPU section due to a
command forwarded by the user (not yet implemented);